EATON - MOELLER EMR6-RC690 EMR6-RC690 184775 Y7-184775 EATON ELECTRIC Insulation monitoring relays, 0 690 V AC, 0 1000 V DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EMR6-RC690 184775 Y7-184775 EATON ELECTRIC Insulation monitoring relays, 0 690 V AC, 0 1000 V DC

EMR6-RC690

184775

Y7-184775

EATON - MOELLER

1 Pcs.

Insulation monitoring relays, 0 - 690 V AC, 0 - 1000 V DC EMR6-RC690 Eaton Moeller® series EMR6 Insulation monitoring relays, 0 - 690 V AC, 0 - 1000 V DC Insulation monitoring relays, Product range: EMR Measuring and monitoring relays, Coupling module, Expands the rated voltage range for the EMR6-R400-A-2 to 690 V AC or 1000 V DC, no supply voltage required, Rated operating voltage for the supply system being monitored: 0 - 690 V AC, 0 - 1000 V DC, Mounting position: As required, Fixing: Snap fixing, top-hat rail IEC/EN 60715, Width: 45 mm, Standards: IEC/EN 60255-6,

Automation > Insulation and earth fault monitoring relay
Relay timers (KETR, KEMR, KESR)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series EMR6 Insulation monitoring relay
Catalog Number
184775
Model Code
EMR6-RC690
EAN
4015081788118
Product Length/Depth
100 mm
Product Height
78 mm
Product Width
45 mm
Product Weight
0.179 kg
Certifications
IEC/EN 60255-6

Features & Functions

Electric connection type
Screw connection
Functions
For mixed system
Voltage measurement - min
0 V
Voltage measurement - max
1000 V

General

Cable length
10 m
Degree of protection
Enclosure: IP50
Terminals: IP20
Lifespan, mechanical
30,000,000 Operations
Mounting position
As required
Overvoltage category
III
Pollution degree
3
Product category
EMR Measuring and monitoring relays
Rated impulse withstand voltage (Uimp)
4000 V AC
Shock resistance
Class 2
LED indicator
Status indication of Faults at L-: Red LED
Status indication of Supply voltage: Green LED
Status indication of Faults at L+: Red LED
Type
Insulation monitoring relay
Voltage type
AC/DC
Voltage type
AC/DC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Ambient storage temperature - min
40 °C
Ambient storage temperature - max
85 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30

Electro magnetic compatibility

Air discharge
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
Burst impulse
According to IEC/EN 61000-4-4, level 3
Electromagnetic compatibility
According to IEC/EN 60947-6-2
Immunity to line-conducted interference
Level 3 (according to IEC/EN 61000-4-6)
Immunity to radiation
Level 3 (according to IEC/EN 61000-4-3)
Surge rating
According to IEC/EN 61000-4-5 Level 4

Terminal capacities

Connection type
Snap fixing, top-hat rail IEC/EN 60715
Terminal capacity (flexible with ferrule)
2 x 0.5-1.5 mm²
Terminal capacity (flexible with ferrule AWG)
2 x 18-16
Terminal capacity (solid)
1 x 0.5-2.5 mm²
Terminal capacity (solid AWG)
18 - 14
Screwdriver size
5.5 x 0.8 mm, Terminal screw
Tightening torque
Min. 0.5 Nm, Screw terminals
0.8 Nm, Screw terminals

Power supply

Duty factor
100 %, Power supply
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Rated frequency - min
15 Hz
Rated frequency - max
60 Hz
Rated operational voltage of monitored supply system
0 - 1000 V DC
0 - 690 V AC
Voltage tolerance
0.85 x Uc
1.1 x Uc

Relay output contacts

Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
0
Lifespan, electrical
100,000 Operation (at 230 V, AC-12, 4 A)
Rated operational current (Ie)
5 A at AC-12, 230 V
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
3 A
Rated operational current (Ie) at DC-13, 24 V
2.5 A
Rated operational voltage (Ue) - min
0 V
Rated operational voltage (Ue) - max
690 V
Short-circuit protection rating
Max. 10 A Fast/gL, Fuse, Relay output contacts
Short-circuit protection rating
Max. 10 A Fast/gL, Fuse, Relay output contacts

ETIM for 184775 Relays (EC001444)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) No
Function (EF000030) For mixed system
External power supply required (EF003292) No
Voltage type (supply voltage) (EF002991) AC/DC
Supply voltage AC 50 Hz (EF007532) 0 V
Supply voltage AC 60 Hz (EF007533) 0 V
Supply voltage DC (EF007534) 0 V
Voltage measuring range (EF002486) 0 V
Rated operating frequency (EF007024) 15 Hz
Line capacity (EF003419) 20 µF
Response value impedance 1 (EF008202) 1 kOhm
Response value impedance 2 (EF008203) 1 kOhm
Indication of insulation value (EF003422) No
Error registration possible (EF003423) No
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 0
Voltage type (operating voltage) (EF005294) AC/DC
Operating voltage AC 50 Hz (EF008206) 0 V
Operating voltage AC 60 Hz (EF008207) 0 V
Operating voltage DC (EF008208) 0 V
Width (EF000008) 45 mm
Height (EF000040) 78 mm
Depth (EF000049) 100 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.