A level monitoring relay provides automated oversight of conductive liquid levels in industrial processes, preventing equipment damage and ensuring consistent fluid storage levels. This Eaton Moeller EMR6-N1000-N-1 device integrates adjustable sensitivity and reliable contact switching for standard control panel integrations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 110 V
- Supply voltage AC 60 Hz (EF007533): 110 V
- Number of inputs for electrodes (EF003427): 3
- Min. adjustable operate delay time (EF008195): 0 s
- Max. permitted operate delay time (EF008194): 0 s
- Min. adjustable off-delay time (EF008192): 0 s
- Max. permitted off-delay time (EF008191): 0 s
- Physical measurement principle (EF008238): Conductive
- Cascadable (EF000507): No
- Response value sensitivity adjustable (EF003429): Yes
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as change-over contact (EF008257): 1
More info
▲General specifications
RCM
EAC
UL
IEC/EN 60255-6
RMRS
EN 61557
CSA
DNV
Features & Functions
Fill level of conductive liquids
General
Enclosure: IP50
Status indication of active release delay: Green, flashing light
Status indication of Supply voltage: Green LED
Status indication of Output relay excited: Yellow, solid light (R)
Status indication of Min and Max occupied: Yellow, solid light
Status indication of energized output relay: Yellow LED
Status indication of Supply voltage: Green, solid light
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule
0.8 Nm, Screw terminals
Timing cycle
Power supply
110 - 130 V AC, 50/60 Hz
1.1 x Uc
Measuring circuits
Earth reference sensor, C, Sensor inputs, Measuring circuits
Maximum level, MAX, Sensor inputs, Measuring circuits
Relay output contacts
3 A at AC-15, 230 V
2 A at DC-12, 24 V