View larger
EMR6-IM15-A-1 184781 Y7-184781 EATON ELECTRIC Current monitoring relays, 0.3 1.5 A, 1 5 A, 3 15 A, 24 240 V ..
EMR6-IM15-A-1
184781
Y7-184781
EATON - MOELLER
1 Pcs.
Automation > Current monitoring relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Current monitoring relays like the Eaton Moeller EMR6-IM15-A-1 serve as frontline defenders for electrical assets by observing operating currents within safe thresholds. Engineers install these devices in power distribution panels to trigger alarms or disconnect supplies during hazardous overloads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- External power supply required (EF003292): No
- Voltage type (supply voltage) (EF002991): AC/DC
- Supply voltage AC 50 Hz (EF007532): 24 V
- Supply voltage AC 60 Hz (EF007533): 24 V
- Supply voltage DC (EF007534): 24 V
- Voltage measuring range (EF002486): 24 V
- Type of current (EF000143): AC/DC
- Current measuring range (EF000417): 0.3 A
- Response value amperage 1 (EF008204): 3 A
- Response value amperage 2 (EF008205): 0.3 A
- Single-phase under current possible (EF003405): Yes
- Three-phase under current possible (EF003406): No
- Single-phase overcurrent possible (EF003407): Yes
- Three-phase overcurrent possible (EF003408): No
More info
▲General specifications
EAC
CSA-C22.2 No. 14
CCC
RMRS
UL 508
Features & Functions
Single-phase under current possible
Monitoring of single-phase DC and AC networks
Single-phase over current possible
DC-voltage under current
Undercurrent
General
Enclosure: IP50
Status indication of Supply voltage: Green, solid light
Status indication of measured value: Red LED
Other states depending on fault (see IL): Measured value
Status indication of Supply voltage: Green LED
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
Min. 0.6 Nm, Screw terminals
Timing cycle
Switch-on delay: none = 0 or adjustable from 0.1 to 30 s
0.06 %/°C, Time error within temperature range
30 s, Reset delay/Off-delay time
0.5 % Error within supply voltage (Measuring circuits)
Power supply
24 - 240 V AC, 50/60 Hz
1.1 x Uc
Measuring circuits
Input B2-C: 0.01 - 0.1 A
Input B3-C: 0.1 - 1 A
Relay output contacts
4 A at DC-12, 24 V