View larger
EMR6-I15-B-1 184755 Y7-184755 EATON ELECTRIC Current monitoring relays, 0.3 1.5 A, 1 5 A, 3 15 A, 24 240 V A..
EMR6-I15-B-1
184755
Y7-184755
EATON - MOELLER
1 Pcs.
Automation > Current monitoring relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller current monitoring relay provides configurable supervision of electrical loads to prevent damage from overcurrent and undercurrent states. These industrial protection devices ensure that equipment operates safely within established electrical thresholds across varied applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- External power supply required (EF003292): No
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 220 V
- Supply voltage AC 60 Hz (EF007533): 220 V
- Voltage measuring range (EF002486): 220 V
- Type of current (EF000143): AC
- Current measuring range (EF000417): 0.3 A
- Response value amperage 1 (EF008204): 0.3 A
- Response value amperage 2 (EF008205): 3 A
- Single-phase under current possible (EF003405): Yes
- Three-phase under current possible (EF003406): No
- Single-phase overcurrent possible (EF003407): Yes
- Three-phase overcurrent possible (EF003408): No
- Single-phase hysteresis possible (EF003394): No
More info
▲General specifications
UL 508
CSA-C22.2 No. 14
RMRS
CCC
GL
Features & Functions
DC-voltage under current
Monitoring of single-phase DC and AC networks
Single-phase under current possible
DC-voltage over current
Undercurrent
General
Terminals: IP20
Status indication of Output relay excited: Yellow, solid light
Status indication of energized output relay: Yellow LED
Status indication of Supply voltage: Green, solid light
Status indication of active release delay: Green, flashing light
Status indication of Supply voltage: Green LED
Status indication of measured value: Red LED
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
0.8 Nm, Screw terminals
Timing cycle
0.5 % Error within supply voltage (Measuring circuits)
0.5 %, Time error within supply voltage
Adjustable from 0.1 – 30 s, Reset delay/Off-delay time
Power supply
1.1 x Uc
Measuring circuits
Input B3-C: 3 - 15 A
Input B2-C: 1 - 5 A
Relay output contacts
4 A at DC-12, 24 V