View larger
EMR6-AWN280-K-1 184769 Y7-184769 EATON ELECTRIC Phase monitoring relays, Multi-functional, 180 280 V AC, 50/..
EMR6-AWN280-K-1
184769
Y7-184769
EATON - MOELLER
1 Pcs.
Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller EMR6-AWN280-K-1 184769 Y7-184769 EATON ELECTRIC Phase monitoring relays, Multi-functional, 180 280 V AC, 50/.. is an electrical protection device utilized in industrial control panels to safeguard sensitive machinery against phase loss, incorrect phase sequence, and voltage fluctuations. Network monitoring relays continually evaluate grid conditions to prevent equipment damage and unplanned downtime by triggering control circuits when parameters deviate from safe thresholds. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- External power supply required (EF003292): No
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 180 V
- Supply voltage AC 60 Hz (EF007533): 180 V
- Phase sequence monitoring (EF003412): Yes
- Phase failure detection (EF003413): Yes
- Function under voltage detection (EF003414): Yes
- Function over voltage detection (EF003415): Yes
- Phase imbalance monitoring (EF003416): Yes
- Voltage measuring range (EF002486): 180 V
- Min. adjustable delay-on energization time (EF008190): 0.1 s
- Max. permitted delay-on energization time (EF008189): 30 s
- Min. adjustable off-delay time (EF008192): 0.1 s
- Max. permitted off-delay time (EF008191): 30 s
More info
▲General specifications
UL
GL
CSA
CCC
Features & Functions
Automatic phase sequence correction (can be disabled)
Multi-functional
Under voltage detection
Phase failure detection
Phase sequence (can be deactivated)
Overvoltage
Undervoltage
Phase imbalance monitoring
Neutral cable break
Imbalance
Phase sequence monitoring
General
Enclosure: IP50
Status indication of Phase sequence fault: Red, flashing light (F1 and F2 alternating)
Status indication of Imbalance: Red, solid light (F1 and F2)
Status indication of Delay time running: Yellow, flashing light (R/T)
Status indication of Supply voltage: Yellow, solid light
Status indication of Overvoltage: F1 red, solid light
Status indication of Supply voltage: Yellow LED
Status indication of Phase failure: F1 red, solid light and F2 red, flashing light
Status indication of Undervoltage: Red LED (F2 on)
Status indication of Undervoltage: F2 red, solid light
Status indication of Open neutral conductor: F1 red, solid light and F2 red, flashing light
Status indication of Relay energized: Yellow, solid light (R)
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule
0.8 Nm, Screw terminals
Timing cycle
0.25 s, Response delay time
0.06 %/°C, Time error within temperature range
0.5 % Error within supply voltage (Measuring circuits)
0.5 %, Time error within supply voltage
Power supply
0.85 x Uc
Measuring circuits
Relay output contacts
3 A at AC-15, 230 V
4 A at AC-12, 230 V
2 A at DC-13, 24 V