View larger
EMR6-AWN170-E-1 184768 Y7-184768 EATON ELECTRIC Phase monitoring relays, Multi-functional, 90 170 V AC, 50/6..
EMR6-AWN170-E-1
184768
Y7-184768
EATON - MOELLER
1 Pcs.
Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller EMR6-AWN170-E-1 is a phase monitoring relay designed to continuously supervise three-phase AC networks for voltage anomalies, phase loss, and incorrect rotation. Engineers deploy these devices in control panels to protect sensitive machinery, motors, and automated systems from electrical supply failures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- External power supply required (EF003292): No
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 90 V
- Supply voltage AC 60 Hz (EF007533): 90 V
- Phase sequence monitoring (EF003412): Yes
- Phase failure detection (EF003413): Yes
- Function under voltage detection (EF003414): Yes
- Function over voltage detection (EF003415): Yes
- Phase imbalance monitoring (EF003416): Yes
- Voltage measuring range (EF002486): 90 V
- Min. adjustable delay-on energization time (EF008190): 0.1 s
- Max. permitted delay-on energization time (EF008189): 30 s
- Min. adjustable off-delay time (EF008192): 0.1 s
- Max. permitted off-delay time (EF008191): 30 s
More info
▲General specifications
IEC
CSA
UL
GL
Features & Functions
Imbalance threshold values adjustable 2 - 25 % of mean value of phase voltages
Under voltage detection
Multi-functional
Phase failure detection
Phase sequence (can be deactivated)
Undervoltage
Phase imbalance monitoring
Imbalance
Phase failure
Overvoltage
Phase sequence monitoring
General
Enclosure: IP50
Status indication of Undervoltage: Red LED (F2 on)
Status indication of Undervoltage: F2 red, solid light
Status indication of Open neutral conductor: F1 red, solid light and F2 red, flashing light
Status indication of Phase sequence fault: Red, flashing light (F1 and F2 alternating)
Status indication of energized output relay: Green flashing (R)
Status indication of Imbalance: Red, solid light (F1 and F2)
Status indication of Overvoltage: Red LED (F1 on)
Status indication of Phase failure: F1 red, solid light and F2 red, flashing light
Status indication of Overvoltage: F1 red, solid light
Status indication of Supply voltage: Green LED (R on)
Status indication of Relay energized: Yellow, solid light
Status indication of Supply voltage: Green, solid light
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
1 x (0.5-2.5) mm², (1 x (18-14) AWG), solid
0.8 Nm, Screw terminals
Timing cycle
0.2 s, Response delay time
Adjustable from 0.1 – 30 s, Reset delay/Off-delay time
0.5 % Error within supply voltage (Measuring circuits)
0.5 %, Time error within supply voltage
Power supply
1.1 x Uc
Measuring circuits
Relay output contacts
3 A at AC-15, 230 V
2 A at DC-13, 24 V
4 A at DC-12, 24 V