View larger
EMR6-AWM820-J-1 184767 Y7-184767 EATON ELECTRIC Phase monitoring relays, Multi-functional, 530 820 V AC, 50/..
EMR6-AWM820-J-1
184767
Y7-184767
EATON - MOELLER
1 Pcs.
Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for heavy-duty electrical installations, the EMR6-AWM820-J-1 Eaton Moeller phase monitoring relay provides comprehensive multi-functional protection across high-voltage three-phase systems. Panel builders specify these units to continuously monitor supply integrity and prevent equipment damage from voltage extremes.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- External power supply required (EF003292): No
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 530 V
- Supply voltage AC 60 Hz (EF007533): 530 V
- Phase sequence monitoring (EF003412): Yes
- Phase failure detection (EF003413): Yes
- Function under voltage detection (EF003414): Yes
- Function over voltage detection (EF003415): Yes
- Phase imbalance monitoring (EF003416): Yes
- Voltage measuring range (EF002486): 530 V
- Min. adjustable delay-on energization time (EF008190): 0.1 s
- Max. permitted delay-on energization time (EF008189): 30 s
- Min. adjustable off-delay time (EF008192): 0.1 s
- Max. permitted off-delay time (EF008191): 30 s
More info
▲General specifications
GL
IEC
UL
CSA
Features & Functions
Imbalance threshold values adjustable 2 - 25 % of mean value of phase voltages
Over voltage detection
Under voltage detection
Multi-functional
Imbalance
Phase imbalance monitoring
Phase sequence
Overvoltage
Undervoltage
Phase failure
Phase sequence (can be deactivated)
General
Terminals: IP20
Status indication of Phase failure: F1 red, solid light and F2 red, flashing light
Status indication of Relay energized: Yellow, solid light
Status indication of Supply voltage: Green, solid light
Status indication of Overvoltage: Red LED (F1 on)
Status indication of Imbalance: Red, solid light (F1 and F2)
Status indication of Overvoltage: F1 red, solid light
Status indication of Phase sequence fault: Red, flashing light (F1 and F2 alternating)
Status indication of energized output relay: Green flashing (R)
Status indication of Undervoltage: Red LED (F2 on)
Status indication of Supply voltage: Green LED (R on)
Status indication of Phase failure: Red LEDs (F1 on, F2 flashes)
Status indication of Phase sequence error: Red LEDs (F1 and F2 flashing)
Status indication of Undervoltage: F2 red, solid light
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule
Min. 0.6 Nm, Screw terminals
Timing cycle
0.25 s, Response delay time
0.5 % Error within supply voltage (Measuring circuits)
Adjustable from 0.1 – 30 s, Reset delay/Off-delay time
0.5 %, Time error within supply voltage
Power supply
1.1 x Uc
Measuring circuits
Relay output contacts
4 A at AC-12, 230 V
3 A at AC-15, 230 V
4 A at DC-12, 24 V