View larger
EMR6-AWM580-H-1 184765 Y7-184765 EATON ELECTRIC Phase monitoring relays, Multi-functional, 350 580 V AC, 50/..
EMR6-AWM580-H-1
184765
Y7-184765
EATON - MOELLER
1 Pcs.
Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Offering multi-functional network protection, the EMR6-AWM580-H-1 Eaton Moeller phase monitoring relay tracks complex electrical supplies for voltage sags, phase imbalances, and connection faults. System builders integrate these units into electrical distribution gear to ensure critical loads remain isolated during power anomalies.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- External power supply required (EF003292): No
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 350 V
- Supply voltage AC 60 Hz (EF007533): 350 V
- Phase sequence monitoring (EF003412): Yes
- Phase failure detection (EF003413): Yes
- Function under voltage detection (EF003414): Yes
- Function over voltage detection (EF003415): Yes
- Phase imbalance monitoring (EF003416): Yes
- Voltage measuring range (EF002486): 350 V
- Min. adjustable delay-on energization time (EF008190): 0.1 s
- Max. permitted delay-on energization time (EF008189): 30 s
- Min. adjustable off-delay time (EF008192): 0.1 s
- Max. permitted off-delay time (EF008191): 30 s
More info
▲General specifications
UL
GL
IEC
CCC
Features & Functions
Imbalance threshold values adjustable 2 - 25 % of mean value of phase voltages
Phase failure detection
Under voltage detection
Over voltage detection
Phase imbalance monitoring
Phase sequence monitoring
Phase sequence
Undervoltage
Phase failure
Imbalance
Phase sequence (can be deactivated)
General
Enclosure: IP50
Status indication of Supply voltage: Green, solid light
Status indication of Undervoltage: Red LED (F2 on)
Status indication of Undervoltage: F2 red, solid light
Status indication of Imbalance: Red, solid light (F1 and F2)
Status indication of energized output relay: Green flashing (R)
Status indication of Phase sequence fault: Red, flashing light (F1 and F2 alternating)
Status indication of Phase sequence error: Red LEDs (F1 and F2 flashing)
Status indication of Overvoltage: F1 red, solid light
Status indication of Relay energized: Yellow, solid light
Status indication of Phase failure: F1 red, solid light and F2 red, flashing light
Status indication of Supply voltage: Green LED (R on)
Status indication of Phase failure: Red LEDs (F1 on, F2 flashes)
Status indication of Delay time running: Yellow, flashing light
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
1 x (0.5-2.5) mm², (1 x (18-14) AWG), solid
0.8 Nm, Screw terminals
Timing cycle
On-delay/off-delay: none = 0 or adjustable between 0.1 - 30 s
0.5 %, Time error within supply voltage
0.5 % Error within supply voltage (Measuring circuits)
0.06 %/°C, Time error within temperature range
Power supply
1.1 x Uc
Measuring circuits
Relay output contacts
4 A at AC-12, 230 V
4 A at DC-12, 24 V
3 A at AC-15, 230 V