View larger
EMR6-AW300-C-1 184763 Y7-184763 EATON ELECTRIC Phase monitoring relays, Multi-functional, 160 300 V AC, 50/6..
EMR6-AW300-C-1
184763
Y7-184763
EATON - MOELLER
1 Pcs.
Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for comprehensive circuit protection, the Eaton Moeller EMR6-AW300-C-1 phase monitoring relay supervises multi-phase installations against overvoltage, undervoltage, phase loss, and incorrect rotation. Engineers install these devices in control cabinets to ensure automated processes shut down safely during unexpected line disturbances.
Please note that specific pricing, availability, and lead times are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- External power supply required (EF003292): No
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 160 V
- Supply voltage AC 60 Hz (EF007533): 160 V
- Phase sequence monitoring (EF003412): Yes
- Phase failure detection (EF003413): Yes
- Function under voltage detection (EF003414): Yes
- Function over voltage detection (EF003415): Yes
- Phase imbalance monitoring (EF003416): Yes
- Voltage measuring range (EF002486): 160 V
- Min. adjustable delay-on energization time (EF008190): 0.1 s
- Max. permitted delay-on energization time (EF008189): 30 s
- Min. adjustable off-delay time (EF008192): 0.1 s
- Max. permitted off-delay time (EF008191): 30 s
More info
▲General specifications
CSA
GL
UL
IEC
Features & Functions
Over voltage detection
Phase failure detection
Multi-functional
Phase sequence (can be deactivated)
Undervoltage
Phase sequence monitoring
Phase failure
Phase imbalance monitoring
Imbalance
General
Terminals: IP20
Status indication of Phase failure: F1 red, solid light and F2 red, flashing light
Status indication of Undervoltage: F2 red, solid light
Status indication of Supply voltage: Green, solid light
Status indication of Overvoltage: Red LED (F1 on)
Status indication of Phase failure: Red LEDs (F1 on, F2 flashes)
Status indication of Undervoltage: Red LED (F2 on)
Status indication of Delay time running: Yellow, flashing light
Status indication of Supply voltage: Green LED (R on)
Status indication of energized output relay: Green flashing (R)
Status indication of Overvoltage: F1 red, solid light
Status indication of Imbalance: Red, solid light (F1 and F2)
Status indication of Phase sequence fault: Red, flashing light (F1 and F2 alternating)
Status indication of Phase sequence error: Red LEDs (F1 and F2 flashing)
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule
0.8 Nm, Screw terminals
Timing cycle
0.2 s, Response delay time
0.5 % Error within supply voltage (Measuring circuits)
0.06 %/°C, Time error within temperature range
Adjustable from 0.1 – 30 s, Reset delay/Off-delay time
Power supply
0.85 x Uc
Measuring circuits
Relay output contacts
4 A at DC-12, 24 V
3 A at AC-15, 230 V
4 A at AC-12, 230 V