View larger
XNE-GWBR-CANOPEN 140044 Y7-140044 EATON ELECTRIC ECO gateway for XI/ON I/O system, integrated
XNE-GWBR-CANOPEN
140044
Y7-140044
EATON - MOELLER
1 Pcs.
Automation > Fieldbus, decentr. periphery - communication module
Remote I / O Modules XION
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller XNE-GWBR-CANOPEN is an ECO gateway for XI/ON I/O system, integrated that connects decentralized peripheral devices to a master controller. These network gateways translate fieldbus protocols to streamline data flow across automated production lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 18 V
- Voltage type (supply voltage) (EF002991): DC
- Supporting protocol for EtherCAT (EF017564): No
- Supporting protocol for TCP/IP (EF003050): No
- Supporting protocol for PROFIBUS (EF003052): No
- Supporting protocol for CAN (EF003053): Yes
- Supporting protocol for INTERBUS (EF003054): No
- Supporting protocol for ASI (EF003051): No
- Supporting protocol for KNX (EF003055): No
- Supporting protocol for Modbus (EF003057): No
- Supporting protocol for Data-Highway (EF003058): No
- Supporting protocol for DeviceNet (EF003059): No
- Supporting protocol for SUCONET (EF003060): No
- Supporting protocol for LON (EF003017): No
More info
▲General specifications
IEC/EN 61000-6-2
IEC/EN 61131-2
Rated data for terminations according to IEC/EN 60947-7-1
CE
IEC/EN 6113-2
IEC/EN 61000-6-4
Features & Functions
Potential separation
General
Ambient conditions, mechanical
Continuous according to IEC/EN 60068-2-29
Climatic environmental conditions
Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation)
Electro magnetic compatibility
30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3)
Terminal capacities
0.25 - 1.5 mm², solid
0.25 - 1.5 mm², flexible without ferrule
0.25 - 0.75 mm², with ferrules with plastic collar
Electrical rating
Communication
Address range: 1 - 63 decimal
Spring-cage terminals, Field bus/Supply voltage)
Push-In spring-cage terminals, Connection design in TOP direction
50 kBit/s
500 kBit/s, Networking
800 kBit/s, Networking
125 kBit/s, Networking
250 kBit/s
10 kBit/s, Networking
1000 kBit/s, Networking
1000 kBit/s
20 kBit/s
Setting through DIP switch or automatically
50 kBit/s, Networking
250 kBit/s, Networking
500 kBit/s
125 kBit/s
CANopen®, Field bus connection
CAN
Other bus systems