Request QuoteProduct Overview
The Eaton Moeller control relay, part designation EASY-E4-UC-12RCX1, is an expandable logic controller featuring onboard Ethernet connectivity for networked industrial automation. These flexible controllers handle diverse automation tasks, data logging, and remote monitoring across modern manufacturing setups.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 20.4 V
- Supply voltage AC 60 Hz (EF007533): 20.4 V
- Supply voltage DC (EF007534): 10.2 V
- Voltage type (supply voltage) (EF002991): AC/DC
- Switching current (EF000188): 8 A
- Power consumption (EF000346): 3 W
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Number of digital inputs (EF001992): 4
- Number of digital outputs (EF001993): 4
- With relay output (EF003198): Yes
- Number of HW-interfaces industrial Ethernet (EF003020): 1
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
More info
▲General specifications
IEC 60068-2-30
CULus per UL 61010
IEC/EN 61000-4-2
IEC 60068-2-6
IEC/EN 61000-6-2
IEC/EN 61000-6-3
CSA-C22.2 No. 61010
IEC 60068-2-27
IEC/EN 61131-2
EN 50178
UL Listed
UL Category Control No.: NRAQ, NRAQ7
UL File No.: E205091
DNV GL
CE
UL hazardous location class I
UL hazardous location division 2
UL hazardous location group A (acetylene)
UL hazardous location group B (hydrogen)
UL hazardous location group C (ethylene)
UL hazardous location group D (propane)
Features & Functions
Networkable (Ethernet)
Relay output
Real time clock
LCD-display used as status indication of Digital inputs 24 V DC
General
Cable length: ≤ 20 m (screened, Digital inputs 24 V DC)
Number: 4 (I1, I2, I3, I4 - Digital inputs 24 V DC)
Pulse pause ratio: 1:1 (Digital inputs 24 V DC)
Counter frequency: 5 kHz (Digital inputs 24 V DC)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device)
25,000 Operations (Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated)
25,000 Operations (Filament bulb load at 1000 W, 230/240 V AC)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Wall mounting/direct mounting
Rail mounting possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
TCP/IP
2 Hz, Resistive load/lamp load, Relay outputs
10 Hz, Relay outputs
R 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes DC
Ambient conditions, mechanical
Vertical
According to IEC/EN 60068-2-6
10 - 57 Hz, 0.15 mm constant amplitude
Climatic environmental conditions
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Electro magnetic compatibility
2 kV, Supply cable
According to IEC/EN 61000-4-4
1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
According to IEC/EN 61000-4-5, power pulses (Surge), EMC
1 kV, Supply cables, symmetrical, power pulses (Surge), EMC
10 ms
Terminal capacities
0.2 - 4 mm² (AWG 22 - 12), solid
Electrical rating
300000 Operations at AC-15, 250 V AC, 3 A (600 Ops./h)
12 V DC (digital inputs)
12/24 V DC (-15 %/+ 20 % - power supply)
24 V AC (digital inputs)
24 V DC (digital inputs)
20.4 - 26.4 V AC
Max. 300 V AC
24 V AC (-15 %/+10 % - power supply)
240 V AC
Max. 300 V DC
5 A AC, max. thermal continuous current cos ϕ = 1 at B 300 (UL/CSA)
8 A DC, at 24 V DC (UL/CSA)
10 A AC, at 240 V AC (UL/CSA)
Short-circuit rating
Communication
Ethernet: RJ45 plug, 8-pole
Status indication of Ethernet: LED
Cable
100 m, unscreened, Digital inputs 24 V AC
≤ 30 m, screened, Analog inputs
100 m, unscreened, Digital inputs 24 V DC
40 m (max. per input), Digital inputs 24 V DC
Input/Output
± 2 %, (I7, I8) ± 0.12 V, of actual value, within a single device (Analog Inputs)
± 1 %, Repetition accuracy of timing relays (of values)
± 3 %, of actual value, two easy devices (Analog Inputs)
20 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 1 to 0, Debounce ON
0.015 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF
0.015 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF
0.015 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF
0.015 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF
20 ms typ., Digital inputs 12 V DC (I1 - I8), Delay time from 1 to 0, Debounce ON
20 ms typ., Digital inputs 24 V DC (I1 - I8), Delay time from 0 to 1, Debounce ON
Signal offset: 90°
Pulse pause ratio: 1:1
Value range: -2147483648 to +2147483647
Pulse shape: Square
Counter frequency: ≤ 5 kHz
3.3 mA (I1 - I4, at 24 V DC, at signal 1)
1 mA (Analog inputs)
200 mA
Status 0: ≤ 8 V DC (I5 - I8, Digital inputs, 24 V DC)
At signal 0: ≤ 5 V (I1 - I8, sinusoidal, Digital inputs, 24 V DC)
At signal 1: ≥ 15 V (I1 - I8, sinusoidal, Digital inputs, 24 V DC)
Status 1: ≥ 8 V DC (I5 - I8, Digital inputs, 24 V DC)
Signal 0: ≤ 5 V DC (I1 - I4, Digital inputs, 12 V DC)
Status 0: ≤ 15 V DC (I1 - I4, Digital inputs, 24 V DC)
28/28 VA (DC, at R 300)
4
8
> 500 mA (Relay outputs, Recommended for load: 12 V AC/DC)
4 Relay Outputs
Voltage
Current
Number: 4 (I1, I2, I3, I4 - Digital inputs 24 V DC)
≤ 20 m (cable length, screened)
1:1 (Pulse pause ratio)
Square (pulse shape)
10 kHz, Counter frequency
Safety
Between Relay outputs and expansion devices: yes
Between Digital inputs 12 V DC and expansion devices: yes
Between Relay outputs: yes
Between Analog inputs and Outputs: yes
Basic isolation: 600 V AC (Relay outputs)
Between Analog inputs and expansion devices: yes
Between Digital inputs 24 V AC and expansion devices: yes
Between Relay outputs and Power supply: yes
Between Digital inputs 24 V DC and Outputs: yes
Between Analog inputs and Ethernet: yes
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
Between Digital inputs 24 V AC and Ethernet: yes
Between Digital inputs 24 V DC and expansion devices: yes
Between Relay outputs and Inputs: yes
Between Digital inputs 12 V DC and Ethernet: yes
Between Digital inputs 12 V DC and Outputs: yes
Between Digital inputs 24 V DC and Ethernet: yes
300 V AC, Between two contacts, According to EN 50178