View larger
EASY-E4-DC-6AE1 197223 Y7-197223 EATON ELECTRIC I/O expansion, For use with easyE4, 24 V DC, Inputs expansio..
EASY-E4-DC-6AE1
197223
Y7-197223
EATON - MOELLER
1 Pcs.
Automation > Logic module
Easy E4 Nanocontrollers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller EASY-E4-DC-6AE1 is an I/O expansion module engineered to scale control system capabilities. Input expansion modules allow automation engineers to increase the capacity of base controllers by adding extra signal channels for monitoring and managing industrial processes without requiring a complete hardware redesign.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 20.4 V
- Voltage type (supply voltage) (EF002991): DC
- Switching current (EF000188): 0 A
- Power consumption (EF000346): 2.5 W
- Number of analogue inputs (EF001994): 4
- Number of analogue outputs (EF001995): 2
- Number of digital inputs (EF001992): 0
- Number of digital outputs (EF001993): 0
- With relay output (EF003198): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
More info
▲General specifications
IEC/EN 61000-4-2
EN 61010
IEC/EN 61131-2
IEC/EN 61000-6-2
EN 50178
IEC/EN 61000-6-3
CULus per UL 61010
IEC 60068-2-27
IEC 60068-2-30
IEC 60068-2-6
UL Listed
UL Category Control No.: NRAQ, NRAQ7
UL File No.: E205091
DNV GL
CE
UL hazardous location class I
UL hazardous location division 2
UL hazardous location group A (acetylene)
UL hazardous location group B (hydrogen)
UL hazardous location group C (ethylene)
UL hazardous location group D (propane)
Features & Functions
Expansion device
General
Rail mounting possible
Wall mounting/direct mounting
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
MODBUS
Ambient conditions, mechanical
Vertical
10 - 57 Hz, 0.15 mm constant amplitude
According to IEC/EN 60068-2-6
Climatic environmental conditions
Condensation: prevent with appropriate measures
Electro magnetic compatibility
2 kV, Supply cable
2 kV, Signal cable
1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.8 - 1.0 GHz (according to IEC EN 61000-4-3)
According to IEC/EN 61000-4-5, power pulses (Surge), EMC
1 kV, Supply cables, asymmetrical, power pulses (Surge), EMC
≤ 10 ms, Bridging voltage dips
Terminal capacities
0.2 - 4 mm² (AWG 22 - 12), solid
Electrical rating
24 V DC (-15 %/+ 20 % - power supply)
Short-circuit rating
Communication
Cable
≤ 30 m, screened, Analog inputs
10 m, screened, Analog inputs
Input/Output
Current
Voltage
0 - 20 mA, Analog inputs
0 - 10 V DC, Analog inputs
0 - 10 V DC, Analog outputs
4 - 20 mA, Analog inputs
0 - 20 mA, Analog outputs
Safety
Between Analog inputs and Inputs/Outputs: no
Between Analog outputs and Inputs/Outputs: no
Between Analog inputs and expansion devices: yes
Between Analog outputs and Power supply: no
Between Analog outputs and expansion devices: no