View larger
EASY-E4-AC-16RE1 197222 Y7-197222 EATON ELECTRIC I/O expansion, For use with easyE4, 100 240 V AC, 110 220 V..
EASY-E4-AC-16RE1
197222
Y7-197222
EATON - MOELLER
1 Pcs.
Automation > Logic module
Easy E4 Nanocontrollers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An I/O expansion unit such as the Eaton Moeller EASY-E4-AC-16RE1 extends the signal capacity of modular control systems, allowing operators to scale up the number of digital monitoring and switching points in an installation. Such modules are frequently integrated into factory automation panels to manage additional sensors and actuators.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 85 V
- Supply voltage AC 60 Hz (EF007533): 85 V
- Supply voltage DC (EF007534): 85 V
- Voltage type (supply voltage) (EF002991): AC
- Switching current (EF000188): 5 A
- Power consumption (EF000346): 4 W
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Number of digital inputs (EF001992): 8
- Number of digital outputs (EF001993): 8
- With relay output (EF003198): Yes
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
More info
▲General specifications
IEC 60068-2-30
IEC/EN 61131-2
CSA-C22.2 No. 61010
EN 50178
IEC 60664
IEC/EN 61000-4-2
EN 61010
IEC 60068-2-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
IEC 60068-2-6
UL Listed
UL Category Control No.: NRAQ, NRAQ7
UL File No.: E205091
DNV GL
CE
UL hazardous location class I
UL hazardous location division 2
UL hazardous location group A (acetylene)
UL hazardous location group B (hydrogen)
UL hazardous location group C (ethylene)
UL hazardous location group D (propane)
Features & Functions
Expansion device
General
50/60 Hz (Digital inputs, at 24 V DC)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device)
25,000 Operations (Filament bulb load at 500 W, 115/120 V AC)
25,000 Operations (Fluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Front build in possible
TCP/IP
0.5 Hz, Inductive load, Relay outputs
10 Hz, Relay outputs
B 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes AC
Ambient conditions, mechanical
Vertical
10 - 57 Hz, 0.15 mm constant amplitude
According to IEC/EN 60068-2-6
Climatic environmental conditions
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Electro magnetic compatibility
2 kV, Supply cable
According to IEC/EN 61000-4-4
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3)
1 kV, Supply cables, symmetrical, power pulses (Surge), EMC
2 kV, Supply cables, asymmetrical, power pulses (Surge), EMC
Terminal capacities
0.2 - 4 mm² (AWG 22 - 12), solid
Electrical rating
200000 Operations at DC-13, 24 V DC, 1 A (500 Ops./h)
Max. 300 V AC
Max. 300 V DC
110/120 V DC (power supply)
240 V AC
100/110/115/120/230/240 AC (-15 %/+10 %)
5 A AC, max. thermal continuous current cos ϕ = 1 at B 300 (UL/CSA)
8 A DC, at 24 V DC (UL/CSA)
8 A AC, at 240 V AC (UL/CSA)
Short-circuit rating
Communication
Cable
≤ 60 m per input (I1 - I8), Digital inputs 115/230 V AC
40 m (max. permissible per input R1 to R12), Digital inputs 115/230 V AC
Input/Output
32 ms typ., Digital Inputs 100 - 240 V AC 60 Hz (I1 - I8), Delay time from 1 to 0, Debounce OFF
80 ms, Digital inputs 115/230 V AC 50 Hz (I7, I8), Delay time from 0 to 1, Debounce ON
0.5 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF
39 ms typ., Digital Inputs 100 - 240 V AC 50 Hz (I1 - I8), Delay time from 0 to 1, Debounce OFF
32 ms typ., Digital Inputs 100 - 240 V AC 60 Hz (I1 - I8), Delay time from 0 to 1, Debounce OFF
0.5 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF
6 x 0.5 mA (I1 - I8, at 230 V AC, 50 Hz, at signal 1)
Condition 1: 79 - 264 V AC, Digital inputs, 115/230 V AC)
28/28 VA (DC, at R 300)
> 500 mA (Relay outputs, Recommended for load: 12 V AC/DC)
Relay outputs in groups of 1
Voltage
Current
Safety
Between Digital inputs 115/230 V AC and Outputs: yes
Between Digital inputs 115/230 V AC and expansion devices: yes
Between Relay outputs and Inputs: yes
Between Digital inputs 115/230 V AC and base unit: yes
Between Digital inputs 115/230 V AC and Power supply: no
Between Digital inputs 115/230 V AC: no
Basic isolation: 600 V AC (Relay outputs)
Between Relay outputs and Power supply: yes
Between Relay outputs: yes
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
300 V AC, Between two contacts, According to EN 50178