View larger
EASY-E4-AC-12RCX1 197216 Y7-197216 EATON ELECTRIC Control relays, easyE4 (expandable, Ethernet), 100 240 V A..
EASY-E4-AC-12RCX1
197216
Y7-197216
EATON - MOELLER
1 Pcs.
Automation > Logic module
Easy E4 Nanocontrollers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller EASY-E4-AC-12RCX1 is a programmable control relay equipped with Ethernet connectivity for scalable automation and remote monitoring applications. Expandable logic controllers coordinate inputs and outputs across automated processes, providing reliable sequence control for pumps, HVAC units, and manufacturing cells.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 85 V
- Supply voltage AC 60 Hz (EF007533): 85 V
- Supply voltage DC (EF007534): 85 V
- Voltage type (supply voltage) (EF002991): AC
- Switching current (EF000188): 8 A
- Power consumption (EF000346): 4 W
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Number of digital inputs (EF001992): 8
- Number of digital outputs (EF001993): 4
- With relay output (EF003198): Yes
- Number of HW-interfaces industrial Ethernet (EF003020): 1
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
More info
▲General specifications
IEC 60068-2-30
IEC/EN 61000-4-2
IEC/EN 61131-2
EN 61010
IEC 60068-2-27
EN 50178
IEC 60068-2-6
IEC/EN 61000-6-2
CSA-C22.2 No. 61010
IEC 60664
IEC/EN 61000-6-3
UL Listed
UL Category Control No.: NRAQ, NRAQ7
UL File No.: E205091
DNV GL
CE
UL hazardous location class I
UL hazardous location division 2
UL hazardous location group A (acetylene)
UL hazardous location group B (hydrogen)
UL hazardous location group C (ethylene)
UL hazardous location group D (propane)
Features & Functions
Networkable (Ethernet)
Real time clock
Relay output
General
50/60 Hz (Digital inputs, at 24 V DC)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, uncompensated)
25,000 Operations (Filament bulb load at 500 W, 115/120 V AC)
25,000 Operations (Filament bulb load at 1000 W, 230/240 V AC)
25,000 Operations (Fluorescent lamp load 10 x 58 W at 230/240 V AC, with upstream electrical device)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Wall mounting/direct mounting
Rail mounting possible
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
TCP/IP
2 Hz, Resistive load/lamp load, Relay outputs
0.5 Hz, Inductive load, Relay outputs
R 300 Light Pilot Duty, UL/CSA Control Circuit Rating Codes DC
Ambient conditions, mechanical
Vertical
10 - 57 Hz, 0.15 mm constant amplitude
57 - 150 Hz, 2 g constant acceleration
Climatic environmental conditions
Condensation: prevent with appropriate measures
Electro magnetic compatibility
According to IEC/EN 61000-4-4
2 kV, Signal cable
10 V/m at 0.8 - 1.0 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
1 kV, Supply cables, symmetrical, power pulses (Surge), EMC
2 kV, Supply cables, asymmetrical, power pulses (Surge), EMC
Terminal capacities
0.2 - 4 mm² (AWG 22 - 12), solid
Electrical rating
200000 Operations at DC-13, 24 V DC, 1 A (500 Ops./h)
Max. 300 V DC
Max. 300 V AC
100/110/115/120/230/240 AC (-15 %/+10 %)
85 - 264 V AC
240 V AC
1 A DC, at R 300 (UL/CSA)
8 A DC, at 24 V DC (UL/CSA)
5 A AC, max. thermal continuous current cos ϕ = 1 at B 300 (UL/CSA)
Short-circuit rating
Communication
Ethernet: RJ45 plug, 8-pole
Status indication of Power/RUN
Cable
40 m (max. permissible per input I1 to I6), Digital inputs 115/230 V AC
Input/Output
± 2 s/day, Real-time clock to inputs (± 0.2 h⁄Year)
20 ms, Digital inputs 115/230 V AC 50 Hz (I7, I8), Delay time from 1 to 0, Debounce OFF
20 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 1 to 0, Debounce ON
21 ms typ., Digital Inputs 100 - 240 V AC 60 Hz (I1 - I8), Delay time from 0 to 1, Debounce OFF
21 ms typ., Digital Inputs 100 - 240 V AC 60 Hz (I1 - I8), Delay time from 1 to 0, Debounce OFF
16⅔ ms, Digital inputs 115/230 V AC 60 Hz (I7, I8), Delay time from 1 to 0, Debounce OFF
0.03 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 0 to 1, Debounce OFF
0.03 ms typ., Digital Inputs 100 - 240 V DC (I1 - I8), Delay time from 1 to 0, Debounce OFF
2 x 4 mA (I7 - I8, at 115 V AC, 60 Hz, at signal 1)
6 x 0.25 mA (I1 - I6, at 115 V AC, 60 Hz, at signal 1)
2 x 6 mA (I7 - I8, at 230 V AC, 50 Hz, at signal 1)
6 x 0.25 mA (I1 - I8, at 115 V AC, 60 Hz, at signal 1)
Condition 1: 79 - 264 V AC, Digital inputs, 115/230 V AC)
3600/360 VA (AC, at B 300)
4 Relay Outputs
> 500 mA (Relay outputs, Recommended for load: 12 V AC/DC)
Voltage
Current
Safety
Between Digital inputs 115/230 V AC: no
Between Digital inputs 115/230 V AC and base unit: yes
Between Relay outputs and expansion devices: yes
Basic isolation: 600 V AC (Relay outputs)
Between Digital inputs 115/230 V AC and Outputs: yes
Between Relay outputs and Inputs: yes
Between Digital inputs 115/230 V AC and expansion devices: yes
Between Digital inputs 115/230 V AC and Memory card: no
Between Digital inputs 115/230 V AC and Ethernet: yes
Between Digital inputs 115/230 V AC and Power supply: no
Safe isolation according to EN 50178: 300 V AC (Relay outputs)
Between Relay outputs and Power supply: yes
Between Relay outputs: yes
Between Digital inputs 115/230 V AC and Interface: yes
300 V AC, Between two contacts, According to EN 50178