EATON - MOELLER DX-SIN3-065-A DX-SIN3-065-A 184496 EATON ELECTRIC Sine filter, three-phase, 500 V + 0% (50/60 Hz) V AC, 65 A, For use with.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DX-SIN3-065-A 184496 EATON ELECTRIC Sine filter, three-phase, 500 V + 0% (50/60 Hz) V AC, 65 A, For use with..

DX-SIN3-065-A

184496

Y7-184496

EATON - MOELLER

1 Pcs.

Sine filter, three-phase, 500 V + 0% (50/60 Hz) V AC, 65 A, For use with: DA1, DG1 Sine filter, Description: three-phase, For use with: DA1, DG1, Max. permissible connection voltage: 500 V + 0% (50/60 Hz) V AC, Rated operational current: Ie= 62 A

Automation > Accessories/spare parts for frequency controller
Power XL Frequency Converters

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Sine filter, three-phase, 500 V + 0% (50/60 Hz) V AC, 65 A, For use with: DA1, DG1
Sine filter, Description: three-phase, For use with: DA1, DG1, Max. permissible connection voltage: 500 V + 0% (50/60 Hz) V AC, Rated operational current: Ie= 65 A

Delivery program

Product range
Accessories
Accessories
Sine filter
Description
three-phase
For use with
DA1, DG1
Max. permissible connection voltage
500 V + 0% (5 - 150 Hz) V AC
Rated operational current [Ie]
65 A
Inductance [L]
0.75 mH
Instructions
Differential-mode inductance, common-mode inductance: 1.4 mH
Maximum heat dissipation [Pv]
650 W

Technical data

General
Standards
IEC/EN 61558 Part 1 +AA + AC, IEC/EN 61588 Part 20
Operating temperature
-10 - +45 °C
Storage [ϑ]
-25 - +85 °C
Altitude
0 - 1000 a.s.l., up to 4000 with current reduction (see IL) m
Mounting position
Standing vertically, suspended horizontally
Free surrounding areas
> 100 MM
Degree of Protection
IP00
Rated duty factor
100 % DF
Electrical data
Rated operational voltage
3 AC 230 V
3 AC 400 V
Max. permissible connection voltage
500 V + 0% (5 - 150 Hz) V AC
Rated frequency [f]
0 - 120 Hz
Insulation class
H
Rated operational current [Ie]
65 A
Inductance [L]
0.75 mH
Maximum heat dissipation [Pv]
650 W
Voltage sag [Uk]
6.5 %
Connection
Terminations
PE stud

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
65 A
Equipment heat dissipation, current-dependent [Pvid]
650 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-10 °C
Operating ambient temperature max.
+45 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 8.0

Low-voltage industrial components (EG000017) / Accessories/spare parts for frequency controller (EC002025)
Electric engineering, automation, process control engineering / Electrical drive / Static frequency converter / Static frequency converter (accessory) ([email protected] [AFR303003])
Type of accessory/spare part
Filter
Accessory
Yes
Spare part
No

ETIM for 184496 Low-voltage industrial controls and switchgear (EC002025)
Feature Name Feature Value
Type of accessory/spare part (EF000215) Filter
Accessory (EF013236) Yes
Spare part (EF013237) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.