View larger
DS7-340SX012N0-L 171743 Y7-171743 EATON ELECTRIC Soft starter, 12 A, 200 480 V AC, 24 V AC/DC, Frame size FS..
DS7-340SX012N0-L
171743
Y7-171743
EATON - MOELLER
1 Pcs.
Automation > Soft starter
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller soft starter DS7-340SX012N0-L provides efficient control over motor startup characteristics, minimizing mechanical stress and electrical disturbances in industrial setups. Panel builders rely on these reliable devices to protect pumps and fans.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 12 A
- Rated operating voltage Ue (EF002418): 230 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 3 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 5.5 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): No
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 40 °C
- Rated control supply voltage AC 50 Hz (EF003978): 24 V
- Rated control supply voltage AC 60 Hz (EF003979): 24 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): AC/DC
- Integrated motor overload protection (EF007297): No
- Degree of protection (IP) (EF005474): IP20
- Degree of protection (NEMA) (EF011959): 1
More info
▲General specifications
CE
C-Tick
CSA22.2-14
CSA-C22.2 No 0-M91
UL 508
CSA File No.: 2511305
CSA Class No.: 321106
GB 14048.6
UkrSEPRO
IEC/EN 60947-4-2
CSA
UL
CSA-C22.2 No 14-05
Features & Functions
Internal bypass
Min. ramp time 1 s - fast switching (semiconductor contactor)
Suppression of DC components for motors
Soft start function
Potential isolation between power and control sections
Single direction
General
NEMA 1
Ambient conditions, mechanical
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
PKM0-12 (+ CL-PKZ0), Type “1” coordination, Main conducting paths
Motor rating
Terminal capacities
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Main cables
1 x (0.75 - 4) mm², Main cables
2 x (0.75 - 2.5) mm², Main cables
1 x (0.75 - 4) mm², Control circuit cables
18 - 10, Control circuit cables
PZ2, 1 x 6 mm, Terminal screw, Standard screwdriver
1.2 Nm, Screw terminals, Control circuit cables
Control circuit
1.6 mA, Control circuit, Digital inputs, External 24 V
AC operated: 0 - 3 V, AC operated
Input/Output
24 V DC
24 V DC (-15 %/+10 %)
Soft start function
Max. 100 %, Soft start function, Start voltage = turn-off voltage