View larger
DS7-340SX004N0-L 171740 Y7-171740 EATON ELECTRIC Soft starter, 4 A, 200 480 V AC, 24 V AC/DC, Frame size FS1..
DS7-340SX004N0-L
171740
Y7-171740
EATON - MOELLER
1 Pcs.
Automation > Soft starter
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Compact machine builders rely on an Eaton Moeller soft starter to deliver controlled ramp-up times for fractional and standard horsepower motors. These units save valuable DIN-rail space inside control panels while protecting downstream mechanical drives.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated operation current Ie at 40 °C Tu (EF007039): 4 A
- Rated operating voltage Ue (EF002418): 230 V
- Rated power three-phase motor, inline, at 230 V (EF007053): 0.75 kW
- Rated power three-phase motor, inline, at 400 V (EF007054): 1.5 kW
- Function (EF000030): Single direction
- Internal bypass (EF009214): Yes
- With display (EF000458): No
- Torque control (EF009215): No
- Rated surrounding temperature without derating (EF007074): 40 °C
- Rated control supply voltage AC 50 Hz (EF003978): 24 V
- Rated control supply voltage AC 60 Hz (EF003979): 24 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): AC/DC
- Integrated motor overload protection (EF007297): No
- Degree of protection (IP) (EF005474): IP20
- Degree of protection (NEMA) (EF011959): 1
More info
▲General specifications
CSA
C-Tick
CSA22.2-14
CSA-C22.2 No 0-M91
CSA-C22.2 No 14-05
UL 508
GB 14048.6
UkrSEPRO
UL File No.: E251034
CSA File No.: 2511305
UL
CSA Class No.: 321106
IEC/EN 60947-4-2
Features & Functions
Internal bypass contacts
Suppression of DC components for motors
Suppression of closing transients
Single direction
Min. ramp time 1 s - fast switching (semiconductor contactor)
Potential isolation between power and control sections
General
IP20
Ambient conditions, mechanical
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-30
Main conducting paths
3 x 170M1359, Type „2“ coordination (additional with the fuses for coordination type „1“), Main conducting paths
Motor rating
Terminal capacities
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Main cables
1 x (0.75 - 4) mm², Control circuit cables
1 x (0.75 - 4) mm², Main cables
2 x (0.75 - 2.5) mm², Control circuit cables
18 - 10, Control circuit cables
0.6 x 5.5 mm/1 x 6 mm, Terminal screws, Control circuit cables
1.2 Nm
Control circuit
50 mA, Control circuit, Regulator supply
AC operated: 0 - 3 V, AC operated
Input/Output
24 V DC
24 V AC
Soft start function
Max. 100 %, Soft start function, Start voltage = turn-off voltage