View larger
MSC-DE-12-M9(230V50HZ) 121741 Y7-121741 EATON ELECTRIC DOL starter, 3p, 4.0kW/400V/AC3, 100kA, protection el..
MSC-DE-12-M9(230V50HZ)
121741
Y7-121741
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
MSC-DE-12-M9(230V50HZ) 121741 Y7-121741 EATON ELECTRIC DOL starter, 3p, 4.0kW/400V/AC3, 100kA, protection el.. functions as a direct-on-line motor starter engineered to safely switch and protect three-phase AC induction motors. This pre-assembled unit combines disconnecting, switching, and thermal overload protection capabilities within a compact enclosure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 2.2 kW
- Rated operation power at AC-3, 400 V (EF001364): 4 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 0 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 8.5 A
- Rated operation current at AC-3, 400 V (EF009602): 9 A
- Overload release current setting (EF002336): 3 A
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): Adjustable
More info
▲Delivery program
IE3-ready devices are identified by the logo on their packaging.
Mechanical connection element and electrical electric contact module
The DOL starters (complete units) consist of a PKE motor protective circuit breaker and a DILM contactor.
With the adapter-less top-hat rail mounting of starters up to 15 A, only the motor protective circuit breaker on the top-hat rail requires an adapter.
The contactors are provided with mechanical support via a mechanical connection element.
Control wire guide with max. 6 conductors up to 2.5 mm external diameter or 4 conductors up to 3.5 mm external diameter.
The connection of the main circuit between PKE and contactor is established with electrical contact modules.
When using DILA-XHIT… auxiliary contacts with MSC-DE-... DOL starters, the plug-in electrical connectors can be removed without removing the front-mounted auxiliary contact.
Cannot be combined with NHI‐E…PKZ0‐C.
The MSC-DEA... DOL starters are prepared for communication via SmartWire-DT. For this, the PKE-SWD-32 communication module must be added.
Motor rating | Rated motor current | |||||
|---|---|---|---|---|---|---|
AC-3 | ||||||
| 220 V 230 V 240 V | 380 V 400 V | 415 V | ||||
| Iq= 100 kA | Iq=100 kA | Iq= 50 kA | ||||
| P | I | I | I | |||
| kW | A | A | A | |||
| 0.75 | 3.2 | - | - | |||
| 1.1 | 4.6 | - | - | |||
| 1.5 | 6.3 | 3.6 | 3.6 | |||
| 2.2 | 8.7 | 5 | 5 | |||
| 3 | - | 6.6 | 6.6 | |||
| 4 | - | 8.5 | 8.5 |
Technical data
700 (Class 10)
900 (Class 15)
1000 (Class 20) ms
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. ms
DILM contactors, see contactor product group
DILET timing relay, ETR, see contactors, electronic timing relays product group