View larger
EMS-DOS-T-2,4-24VDC 170103 EMS-DOS-T-2P4-24VDC EATON ELECTRIC DOL starter 2.4A, emergency stop
EMS-DOS-T-2,4-24VDC
170103
EMS-DOS-T-2P4-24VDC
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DOL starter EMS-DOS-T-2,4-24VDC is a direct-on-line motor starter designed for the safe starting and stopping of three-phase loads in industrial automation systems. These devices provide essential switching capability and overload protection to prevent motor burnout in manufacturing environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): No
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0.37 kW
- Rated operation power at AC-3, 400 V (EF001364): 0.75 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 0.736 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 2.4 A
- Rated operation current at AC-3, 400 V (EF009602): 2.4 A
- Overload release current setting (EF002336): 0.18 A
- Ambient temperature, upper operating limit (EF009603): 60 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): CLASS 10
More info
▲Delivery program
Motor protection
Emergency-stop actuator
Circuit design: safety output stage with bypass, three-phase disconnect.
II (2) D [Ex t] [Ex p]
Technical data
UL508
Motor feeder at bottom
1 x AWG20 - 14 mm2
1 x AWG20 - 14 mm2
2 x AWG20 - 16 mm2
20 (automatic restart) min.
If ≧ 67, pick-up time of 1.8 s %
If ≧ 67, pick-up time of 1.8 s %
50 kA, 415 V AC: PKM0-4
15 kA, 415 V AC: PKM0-6,3
1.4 - 2 GHz: 10
2.0 - 2.7 GHz: 3 V/m
EN 61000-6-3, Class A (emitted interference, radiated)
IEC/EN 61000-4-4, level 3 kV
2 kV (asymmetrical)
according to IEC/EN 61000-4-5
See Safety manual PU05907001Z.
λsu [FIT]: 1582
λdd [FIT]: 269
λdu [FIT]: 2,4
SGF [%]: 99,8
DCS [%]: 2,9
DC [%]: 99
PFH [1/h]: 2,4 x 10-9
SIL: 3
See Safety manual PU05907001Z.