View larger
DM1-347D6EB-S20S-EM 3-5011-004A EATON ELECTRIC DM1-347D6EB-S20S-EM
DM1-347D6EB-S20S-EM
3-5011-004A
3-5011-004A
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DM1-347D6EB-S20S-EM variable frequency drive regulates three-phase motor performance across general automation tasks. These controllers allow operators to adjust motor velocities dynamically, minimizing mechanical wear and optimizing throughput in industrial plants.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 7.6 A
- Power consumption (EF000346): 150 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UkrSEPRO
UL Listed
IEC/EN 61800-2
C-Tick
IEC/EN 61800-5-1
UL
CE
UL 508C
RoHS, ISO 9001
CE marking
UL File No.: E134360
EAC
IEC/EN61800-3
IEC/EN61800-5
UL Category Control No.: NMMS, NMMS7
IEC/EN 61800-3
CSA-C22.2 No. 274-17
Certified by UL for use in Canada
CUL
UL report applies to both US and Canada
General
C2 ≤ 5 m, maximum motor cable length
BACnet TCP
DeviceNet, optional
PROFIBUS, optional
Modbus RTU, built in
SmartWire-DT, optional
Modbus TCP, built in
BACnet MS/TP, built in
Ethernet IP, built in
Yes
NEMA Other
Parameterization: Power Xpert inControl
Parameterization: Keypad
Temperature-controlled fan
Setpoint potentiometer
7-digital display assembly
Internal DC link
IGBT inverter
Radio interference suppression filter
Breaking resistance
Control unit
PC connection
C1: with external filter, for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 3000 m
Max. 2000 m for Corner Grounded TN Systems
Above 1000 m with 1 % derating per 100 m
Main circuit
PM motors
Torque regulation
Sensorless vector control (SLV)
U/f control
400 V AC, 3-phase
480 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Motor rating
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Max. 30 % MN, Standard - Main circuit