View larger
DILMS50-22(230V50HZ,240V60HZ) 191747 Y7-191747 EATON ELECTRIC Safety device, 3 pole + 2 N/O + 2 N/C, 22 kW/4..
DILMS50-22(230V50HZ,240V60HZ)
191747
Y7-191747
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered as an Eaton Moeller safety device, part number DILMS50-22(230V50HZ,240V60HZ) provides reliable circuit control and load management across commercial and industrial machinery. Such devices serve a critical role in electrical panels by protecting systems and ensuring proper operational sequencing. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 230 V
- Rated control supply voltage AC 60 Hz (EF003979): 240 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 80 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 50 A
- Rated operation power at AC-3, 400 V (EF001364): 22 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 21 A
- Rated operation power at AC-4, 400 V (EF008496): 10 kW
- Rated operation power NEMA (EF011960): 29.8 kW
- Modular version (EF001126): No
- Width (EF000008): 55 mm
More info
▲General specifications
UL 60947-4-1
CSA File No.: 012528
UL
CSA-C22.2 No. 60947-4-1-14
UL Category Control No.: NLDX
IEC/EN 60947
IEC/EN 60947-4-1
CSA Class No.: 2411-03, 3211-04
CSA
CE
UL File No.: E29096
General
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (0.75 - 35) mm², Main cables
1 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 16) mm², Main cables
2 x (0.75 - 16) mm², Main cables
1 x (0.75 - 2.5) mm², Control circuit cables
18 - 14, Control circuit cables
1 x (16 - 50) mm², Main cables
M6, Terminal screw, Main cables
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
3.3 Nm, Screw terminals, Main cables
Electrical rating
Short-circuit rating
250 A, max. Fuse, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
100 A, max. CB, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
Conventional thermal current Ith
Switching capacity
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Magnet system
4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
19 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Motor rating
Contacts
Special purpose ratings
79 A (600V 60Hz 3phase, 347V 60Hz 1phase)
10 HP, 200 V 60 Hz 3-ph, (UL/CSA)
32.2 A, 200 V 60 Hz 3-ph, (UL/CSA)
40 A, 480 V 60 Hz 3-ph, (UL/CSA)
40 HP, 600 V 60 Hz 3-ph, (UL/CSA)
15 HP, 240 V 60 Hz 3-ph, (UL/CSA)
42 A, 240 V 60 Hz 3-ph, (UL/CSA)
41 A, 600 V 60 Hz 3-ph, (UL/CSA)
79 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
74 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)