Built for safety-critical industrial automation applications, this Eaton Moeller safety contactor includes electronically compatible auxiliary contacts to monitor machine status securely. Safety devices protect personnel and equipment by ensuring positive-guided switching behavior in emergency stop circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILMS17-R23(RDC24)
- Catalogue code: 191724
- Catalogue title: DILMS17-R23(RDC24) 191724 Y7-191724 EATON ELECTRIC Safety device, 3 pole+2N/O+3N/C, electronically-compatibl..
- Product description: General specifications Product Name Eaton Moeller® series DILMS Safety contactor Catalog Number 191724 Model Code DILMS17-R23(RDC24) EAN 4015081922376 Product Length/Depth 138 mm Product Height 85 mm Product Width 45 mm
- Manufacturer summary: Safety device, 3 pole+2N/O+3N/C, electronically-compatible auxiliary contact, 7,5 kW/400V/AC3, DC operated DILMS17-R23(RDC24) Eaton Moeller® series DILMS Safety contactor, 380 V 400 V: 7.5 kW, 2 N/O, 3 NC, RDC 24: 24 - 2
More info
▲General specifications
UL
UL 60947-4-1
VDE 0660
CSA File No.: 012528
UL Category Control No.: NLDX
UL File No.: E29096
CE
CSA
IEC/EN 60947-4-1
IEC/EN 60947
CSA-C22.2 No. 60947-4-1-14
General
Mirror contact (not for microswitches)
Suppressor circuit in actuating electronics
Electronically compatible microswitch N/O
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 10) mm², Main cables
1 x (0.75 - 16) mm², Main cables
1 x (0.75 - 16) mm², Main cables
1 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 10) mm², Main cables
Single 18 - 6, double 18 - 8, Main cables
M5, Terminal screw, Main cables
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
3.2 Nm, Screw terminals, Main cables
Electrical rating
Short-circuit rating
5 kA, SCCR (UL/CSA)
125 A, max. Fuse, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
10/65 kA, CB, SCCR (UL/CSA)
125/70 A, Class J, max. Fuse, SCCR (UL/CSA)
10/100 kA, Fuse, SCCR (UL/CSA)
10/22 kA, CB, SCCR (UL/CSA)
50/32 A, max. CB, SCCR (UL/CSA)
Conventional thermal current Ith
Switching capacity
10 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)
Magnet system
0.6 - 0.15 x UC, DC operated
Motor rating
Contacts
Special purpose ratings
40 A (480V 60Hz 3phase, 277V 60Hz 1phase)
108 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
11 A, 600 V 60 Hz 3-ph, (UL/CSA)
11 A, 200 V 60 Hz 3-ph, (UL/CSA)
3 HP, 240 V 60 Hz 3-ph, (UL/CSA)
9.6 A, 240 V 60 Hz 3-ph, (UL/CSA)
11 A, 480 V 60 Hz 3-ph, (UL/CSA)
10 HP, 600 V 60 Hz 3-ph, (UL/CSA)
3 HP, 200 V 60 Hz 3-ph, (UL/CSA)
30 A, FLA 600 V 60 Hz 3phase; (CSA)
240 A, LRA 480 V 60 Hz 3phase; (CSA)
40 A, FLA 480 V 60 Hz 3phase; (CSA)
40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)