DILMF95(RAC120) 104476 Y7-104476 EATON ELECTRIC Contactor, 4p, 160A/AC1
DILMF95(RAC120)
104476
Y7-104476
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DILMF95(RAC120) DILMF95(RAC120) 104476 Y7-104476 EATON ELECTRIC Contactor, 4p, 160A/AC1 is a robust industrial contactor engineered to handle high-capacity electrical switching tasks and motor control duties. These components provide the switching reliability required in demanding power distribution infrastructure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 100 V
- Rated control supply voltage AC 60 Hz (EF003979): 100 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 110 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 95 A
- Rated operation power at AC-3, 400 V (EF001364): 95 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 50 A
- Rated operation power at AC-4, 400 V (EF008496): 26 kW
- Rated operation power NEMA (EF011960): 55 kW
- Modular version (EF001126): No
- Width (EF000008): 90 mm
More info
▲General specifications
CSA-C22.2 No. 60947-4-1-14
UL Category Control No.: NLDX
CSA
CSA Class No.: 2411-03, 3211-04
UL File No.: E29096
IEC/EN 60947-4-1
UL
UL 60947-4-1
CE
Features & Functions
General
SEMI F47, Magnet systems
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
Climatic environmental conditions
Electro Magnetic Compatibility
Electrical Rating
Short-circuit rating
600 A, max. Fuse, SCCR (UL/CSA)
600 A, max. CB, SCCR (UL/CSA)
300/300 A, Class J, max. Fuse, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
300/300 A, Class J, max. Fuse, SCCR (UL/CSA)
350 A, max. CB, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
Switching time
Magnet system
2 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Motor Rating
Communication
Contacts
Special purpose ratings
100 A (480V 60Hz 3phase, 277V 60Hz 1phase)
570 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
77 A, 600 V 60 Hz 3-ph, (UL/CSA)
62.1 A, 200 V 60 Hz 3-ph, (UL/CSA)
60 HP, 480 V 60 Hz 3-ph, (UL/CSA)
30 HP, 240 V 60 Hz 3-ph, (UL/CSA)
20 HP, 200 V 60 Hz 3-ph, (UL/CSA)
77 A, 480 V 60 Hz 3-ph, (UL/CSA)
80 A, 240 V 60 Hz 3-ph, (UL/CSA)
420 A, LRA 600 V 60 Hz 3phase; (CSA)
540 A, LRA 480 V 60 Hz 3phase; (CSA)
70 A, FLA 600 V 60 Hz 3phase; (CSA)
100 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
100 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)