View larger
DILMF65(RAC240) 104469 Y7-104469 EATON ELECTRIC Timer module, 200-240VAC, 1-30s, star-delta
DILMF65(RAC240)
104469
Y7-104469
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILMF65(RAC240) timer module manages star-delta motor starting sequences, helping to reduce inrush current during heavy machinery startup. Specialized timing elements like this are integrated into motor control centers to automate transition phases and protect mechanical drives.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 190 V
- Rated control supply voltage AC 60 Hz (EF003979): 190 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 230 V
- Operating voltage AC 60 Hz (EF008207): 230 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 85 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 65 A
- Rated operation power at AC-3, 400 V (EF001364): 30 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 25 A
- Rated operation power at AC-4, 400 V (EF008496): 12 kW
- Rated operation power NEMA (EF011960): 37 kW
- Modular version (EF001126): No
- Width (EF000008): 55 mm
More info
▲General specifications
IEC/EN 60947-4-1
UL 60947-4-1
CSA-C22.2 No. 60947-4-1-14
UL Category Control No.: NLDX
CSA File No.: 012528
CSA
CE
CSA Class No.: 2411-03, 3211-04
UL
Features & Functions
General
Also motors with efficiency class IE3
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
Climatic environmental conditions
Electro Magnetic Compatibility
Electrical Rating
Short-circuit rating
10 kA, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
100 A, max. CB, SCCR (UL/CSA)
30/100 kA, Fuse, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
250/150 A, Class J, max. Fuse, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
30 kA, CB, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
Switching time
Magnet system
1.5 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Motor Rating
Communication
Contacts
Special purpose ratings
88 A (480V 60Hz 3phase, 277V 60Hz 1phase)
65 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
15 HP, 240 V 60 Hz 3-ph, (UL/CSA)
30 HP, 480 V 60 Hz 3-ph, (UL/CSA)
40 HP, 600 V 60 Hz 3-ph, (UL/CSA)
10 HP, 200 V 60 Hz 3-ph, (UL/CSA)
41 A, 600 V 60 Hz 3-ph, (UL/CSA)
42 A, 240 V 60 Hz 3-ph, (UL/CSA)
40 A, 480 V 60 Hz 3-ph, (UL/CSA)
88 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)