Request QuoteProduct Overview
Built for massive industrial power distribution systems, this Eaton Moeller contactor handles extreme electrical loads in high-capacity motor and plant automation networks. Large-format contactors provide secure circuit isolation and heavy-duty switching for demanding infrastructure applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILM750/22(RA110)
- Catalogue code: 208221
- Catalogue title: DILM750/22(RA110) 208221 Y7-208221 EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 400kW/400V/AC3
- Product description: General specifications Product Name Eaton Moeller® series DILM Contactor Catalog Number 208221 Model Code DILM750/22(RA110) EAN 4015082082215 Product Length/Depth 232 mm Product Height 296 mm Product Width 250 mm Product
- Manufacturer summary: Contactor, 3p+2N/O+2N/C, 400kW/400V/AC3 DILM750/22(RA110) Eaton Moeller® series DILM Contactor, 380 V 400 V 400 kW, 2 N/O, 2 NC, RA 110: 48 - 110 V 40 - 60 Hz/48 - 110 V DC, AC and DC operation, Screw connection
More info
▲General specifications
UL
CSA-C22.2 No. 60947-4-1-14
IEC/EN 60947
UL 60947-4-1
CE
VDE 0660
CSA Class No.: 3211-04
CSA File No.: 012528
IEC/EN 60947-4-1
UL Category Control No.: NLDX
CSA
Global
5,000,000 Operations (AC operated)
1000 mechanical Operations/h (AC operated)
1000 mechanical Operations/h (DC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-3: Normal AC induction motors: starting, switch off during running
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
General
Damp heat, constant, to IEC 60068-2-78
5,000,000 Operations (AC operated)
1000 mechanical Operations/h (AC operated)
1000 mechanical Operations/h (DC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-3: Normal AC induction motors: starting, switch off during running
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Climatic environmental conditions
2 x (0.75 - 2.5) mm², Control circuit cables
2 x (0.75 - 2.5) mm², Control circuit cables
2/0 - 500 MCM, Main cables
M3.5, Terminal screw, Control circuit cables
35 Nm, Main cable connection screw/bolt
Terminal capacities
463 A at up to 525 V (Individual compensation, three-phase capacitors, open)
800 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
4800 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
800 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Electrical rating
2000 A, max. Fuse, SCCR (UL/CSA)
1200 A, max. CB, SCCR (UL/CSA)
2000 A, max. Fuse, SCCR (UL/CSA)
1200 A, max. CB, SCCR (UL/CSA)
85 kA, Fuse, SCCR (UL/CSA)
2000 A, max. Fuse, SCCR (UL/CSA)
1200 A, max. CB, SCCR (UL/CSA)
85 kA, CB, SCCR (UL/CSA)
463 A at up to 525 V (Individual compensation, three-phase capacitors, open)
800 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
4800 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
800 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Short-circuit rating
Conventional thermal current Ith
15 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)
Switching capacity
Sealing - Pick-up phase (0 - 0.7 x Uc min: Contactor does not switch on
Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor
Sealing - Voltage interruptions (0 - 0.2 x Uc min ≤ 10 ms: Time is bridged successfully
Sealing - Voltage interruptions 0 - 0.2 x Uc min) > 10 ms: Drop-out of the contactor
Sealing - Excess voltage (1.15 - 1.3 x Uc max): Contactor remains switched on
Sealing - Voltage drops (0.6 - 0.7 x Uc min: Contactor remains switched on
Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on with certainty
AC operated: 0.2 x US max - 0.6 x US min, AC operated
0.7 - 1.15 V DC x Us
800 VA, Pull-in power, Coil in a cold state and 1.0 x Us
700 W, Pull-in power, Coil in a cold state and 1.0 x Us
10.3 W, Coil in a cold state and 1.0 x Us
10.3 W, Coil in a cold state and 1.0 x Us
Magnet system
800 VA, Pull-in power, Coil in a cold state and 1.0 x Us
700 W, Pull-in power, Coil in a cold state and 1.0 x Us
10.3 W, Coil in a cold state and 1.0 x Us
10.3 W, Coil in a cold state and 1.0 x Us