View larger
DILM250-S/22(110-120V50/60HZ) 274189 Y7-274189 EATON ELECTRIC Contactor, 3p+2N/O+2N/C, 132kW/400V/AC3
DILM250-S/22(110-120V50/60HZ)
274189
Y7-274189
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DILM250-S/22(110-120V50/60HZ) is a high-capacity power contactor deployed in heavy industrial environments to switch large electrical loads and major industrial motors. Its rugged construction supports demanding power distribution networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 110 V
- Rated control supply voltage AC 60 Hz (EF003979): 110 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Number of normally open contacts as main contact (EF001374): 3
- Type of electrical connection of main circuit (EF006819): Screw connection
- Operating voltage AC 50 Hz (EF008206): 110 V
- Operating voltage AC 60 Hz (EF008207): 110 V
- Rated operation current Ie at AC-1, 400 V (EF001393): 429 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 250 A
- Rated operation power at AC-3, 400 V (EF001364): 132 kW
- Rated operation current Ie at AC-4, 400 V (EF008495): 200 A
- Rated operation power at AC-4, 400 V (EF008496): 110 kW
- Rated operation power NEMA (EF011960): 149 kW
- Modular version (EF001126): false
- Width (EF000008): 140 mm
More info
▲General specifications
IEC/EN 60947-4-1
CSA Class No.: 3211-04
UL File No.: E29096
UL Category Control No.: NLDX
UL 60947-4-1
UL/CSA
CSA File No. 1017510
North America (UL listed, CSA certified)
EN 45545: Fire protection on railway vehicles
IEC 61373: Vibration and shock, tested for category 1 class B
CE marking
Global
200 Operations/h
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
General
Damp heat, cyclic, to IEC 60068-2-30
200 Operations/h
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Climatic environmental conditions
1 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Control circuit cables
18 - 14, Control circuit cables
M3.5, Terminal screw, Control circuit cables
24 Nm, Main cable connection screw/bolt
Terminal capacities
220 A at up to 525 V (Individual compensation, three-phase capacitors, open)
500 V AC, Between the contacts, According to EN 61140
300 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
2050 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
250 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Electrical rating
700 A, max. Fuse, SCCR (UL/CSA)
18 kA, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
250 A, max. CB, SCCR (UL/CSA)
18 kA, Fuse, SCCR (UL/CSA)
18 kA, CB, SCCR (UL/CSA)
600 A, max. CB, SCCR (UL/CSA)
700 A, Class J, max. Fuse, SCCR (UL/CSA)
220 A at up to 525 V (Individual compensation, three-phase capacitors, open)
500 V AC, Between the contacts, According to EN 61140
300 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
2050 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
250 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Short-circuit rating
Conventional thermal current Ith
1 A, 250 V DC, (UL/CSA)
P300, DC operated (UL/CSA)
Switching capacity
Sealing - Voltage drops (0.6 - 0.7 x Uc min: Contactor remains switched on
Sealing - Voltage interruptions (0 - 0.2 x Uc min ≤ 10 ms: Time is bridged successfully
Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on with certainty
Sealing - Pick-up phase (0 - 0.7 x Uc min: Contactor does not switch on
Sealing - Voltage interruptions 0 - 0.2 x Uc min) > 10 ms: Drop-out of the contactor
Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor
Sealing - Voltage drops (0.2 - 0.6 x Uc min ≤12 ms: Time is bridged successfully
AC operated: 0.25 x US max - 0.6 x US min, AC operated
325 W, Pull-in power, Coil in a cold state and 1.0 x Us
325 W, Pull-in power, Coil in a cold state and 1.0 x Us
4.2 W, Coil in a cold state and 1.0 x Us
6.7 VA, Coil in a cold state and 1.0 x Us
Magnet system
325 W, Pull-in power, Coil in a cold state and 1.0 x Us
325 W, Pull-in power, Coil in a cold state and 1.0 x Us
4.2 W, Coil in a cold state and 1.0 x Us
6.7 VA, Coil in a cold state and 1.0 x Us