View larger
DILM15-10(190V50HZ,220V60HZ) 290056 Y7-290056 EATON ELECTRIC Power Contactor 3-pole + 1 NO to 7.5 kW / 400 V..
DILM15-10(190V50HZ,220V60HZ)
290056
Y7-290056
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller DILM15-10(190V50HZ,220V60HZ) serves as a robust power contactor built to manage electrical motor loads in industrial automation systems. Technicians utilize such dependable switching components within electrical distribution panels for safe equipment operation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILM15-10(190V50HZ,220V60HZ)
- Catalogue code: 290056
- Catalogue title: DILM15-10(190V50HZ,220V60HZ) 290056 Y7-290056 EATON ELECTRIC Power Contactor 3-pole + 1 NO to 7.5 kW / 400 V..
- Product description: General specifications Product Name Eaton Moeller® series DILM contactor Catalog Number 290056 Model Code DILM15-10(190V50HZ,220V60HZ) EAN 4015082900564 Product Length/Depth 75 mm Product Height 68 mm Product Width 45 mm
- Manufacturer summary: Power Contactor; 3-pole + 1 NO; to 7.5 kW / 400 V / AC3; 190 V 50 Hz,220 V 60 Hz DILM15-10(190V50HZ,220V60HZ) Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 7.5 kW, 1 N/O, 190 V 50 Hz, 220 V 60 Hz, AC operatio
More info
▲General specifications
cULus Listed
CSA Certified
CSA Class No. NKCR7
UL Listed file E29184
IEC Rated
UL 508
UL Listed
CSA Std. C22.2 No. 14-10
CSA Class No.: 2411-03, 3211-04
CSA-C22.2 No. 14-05
UL
IEC/EN 60947
UL Category Control No.: NLDX
VDE 0660
CE
IEC/EN 60947-4-1
UL File No.: E29096
CSA File No.: 012528
CSA
Features & Functions
General
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
Ambient conditions, mechanical
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Electro Magnetic Compatibility
Terminal capacities
2 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm²
2, Terminal screw, Pozidriv screwdriver
Electrical Rating
Short-circuit rating
60 A, max. CB, SCCR (UL/CSA)
45 A, max. Fuse, SCCR (UL/CSA)
25 A, Class RK5/ 60 A Class J, max. Fuse, SCCR (UL/CSA)
25 A, Class RK5/60 A, Class J, max. Fuse, SCCR (UL/CSA)
Conventional thermal current
Switching capacity
1 A, 250 V DC, (UL/CSA)
P300, DC operated (UL/CSA)
Switching time
Magnet system
3.4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
4.4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Motor Rating
Communication
Contacts
Safety
400 V AC, Between the contacts, According to EN 61140
Special purpose ratings
20 A (600V 60Hz 3phase, 347V 60Hz 1phase)
90 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
7.8 A, 200 V 60 Hz 3-ph, (UL/CSA)
11 A, 480 V 60 Hz 3-ph, (UL/CSA)
9 A, 600 V 60 Hz 3-ph, (UL/CSA)
7.5 HP, 600 V 60 Hz 3-ph, (UL/CSA)
3 HP, 240 V 60 Hz 3-ph, (UL/CSA)
7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA)
2 HP, 200 V 60 Hz 3-ph, (UL/CSA)
60 A, LRA 600 V 60 Hz 3phase; (CSA)
10 A, FLA 480 V 60 Hz 3phase; (CSA)
10 A, FLA 600 V 60 Hz 3phase; (CSA)
20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)