View larger
DILEM-10-G-C(220VDC) 231672 Y7-231672 EATON ELECTRIC Contactor, 3p+1N/O, 4kW/400V/AC3
DILEM-10-G-C(220VDC)
231672
Y7-231672
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller part number DILEM-10-G-C(220VDC) is a DILEM-10-G-C(220VDC) 231672 Y7-231672 EATON ELECTRIC Contactor, 3p+1N/O, 4kW/400V/AC3 built for reliable electrical load switching in compact industrial control panels. Mini contactors are routinely deployed in machine building and secondary distribution networks to operate small motors, lighting banks, and auxiliary control loops safely. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILEM-10-G-C(220VDC)
- Catalogue code: 231672
- Catalogue title: DILEM-10-G-C(220VDC) 231672 Y7-231672 EATON ELECTRIC Contactor, 3p+1N/O, 4kW/400V/AC3
More info
▲General specifications
UL
CSA-C22.2 No. 14-05
IEC/EN 60947
CE
UL File No.: E29096
IEC/EN 60947-4-1
VDE 0660
CSA
CSA Class No.: 3211-04
UL 508
UL Category Control No.: NLDX
Features & Functions
General
20,000,000 Operations
200,000 Operations (at 240 V, AC-15)
20 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
8 g, N/O auxiliary contact, Basic unit without auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Basic unit without auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
20 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
AC-3: Normal AC induction motors: starting, switch off during running
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
2 x (1 - 2.5) mm²
Electrical rating
0.5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
2.5 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
2.5 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
300 V AC, Between coil and auxiliary contacts, According to EN 61140
300 V AC, Between the contacts, According to EN 61140
300 V AC, Between auxiliary contacts, According to EN 61140
Short-circuit rating
45 A, max. Fuse, SCCR (UL/CSA)
6 A gG/gL, Max. Fuse 500V, Auxiliary contacts, Short-circuit rating without welding
10 A fast, Max. Fuse 500V, Auxiliary contacts, Short-circuit rating without welding
Conventional thermal current Ith
Switching capacity
10 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)
Magnet system
2.3 VA/W at DC (Pick-up/Sealing power)