Eaton Moeller DILEM-01-G-C(110VDC) is a DC-operated mini contactor designed for automated control architectures requiring efficient low-power switching. Such units allow control systems to interface reliably with higher-voltage industrial loads using spring-loaded connection technology. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILEM-01-G-C(110VDC)
- Catalogue code: 231694
- Catalogue title: DILEM-01-G-C(110VDC) 231694 Y7-231694 EATON ELECTRIC Contactor, 3p+1N/C, 4kW/400V/AC3
- Product description: General specifications Product Name Eaton Moeller® series DILEM Mini contactor Catalog Number 231694 Model Code DILEM-01-G-C(110VDC) EAN 4015082316945 Product Length/Depth 54 mm Product Height 58 mm Product Width 45 mm P
- Manufacturer summary: Contactor, 3p+1N/C, 4kW/400V/AC3 DILEM-01-G-C(110VDC) Eaton Moeller® series DILEM Contactor, 110 V DC, 3 pole, 380 V 400 V, 4 kW, Contacts N/C = Normally closed= 1 NC, Spring-loaded terminals, DC operation
More info
▲General specifications
IEC/EN 60947-4-1
UL
UL Category Control No.: NLDX
UL File No.: E29096
CE
IEC/EN 60947
VDE 0660
CSA-C22.2 No. 14-05
CSA Class No.: 3211-04
CSA File No.: 012528
CSA
Features & Functions
General
20,000,000 Operations
150,000 Operations (at 240 V, DC, L/R = 50 ms: 2 contacts in series 0.5 A)
20 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
20 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/C auxiliary contact, Basic unit without auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (1 - 2.5) mm²
Electrical rating
1.5 A at 100 V, DC L/R ≤ 15 ms (with 3 contacts in series)
2.5 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
2.5 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
300 V AC, Between coil and contacts, According to EN 61140
300 V AC, Between coil and auxiliary contacts, According to EN 61140
300 V AC, Between the contacts, According to EN 61140
Short-circuit rating
5 kA, SCCR (UL/CSA)
6 A gG/gL, Max. Fuse 500V, Auxiliary contacts, Short-circuit rating without welding
10 A fast, Max. Fuse 500V, Auxiliary contacts, Short-circuit rating without welding
Conventional thermal current Ith
Switching capacity
10 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Magnet system
2.3 VA/W at DC (Pick-up/Sealing power)