View larger
DILEM-01-C(24V50/60HZ) 231687 Y7-231687 EATON ELECTRIC Contactor, 3p+1N/C, 4kW/400V/AC3
DILEM-01-C(24V50/60HZ)
231687
Y7-231687
EATON - MOELLER
1 Pcs.
Automation > Power contactor, AC switching
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller part number DILEM-01-C(24V50/60HZ) is a DILEM-01-C(24V50/60HZ) 231687 Y7-231687 EATON ELECTRIC Contactor, 3p+1N/C, 4kW/400V/AC3 tailored for space-constrained electrical control architectures. Mini contactors provide essential switching functionality for building automation systems, small assembly lines, and specialized laboratory equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILEM-01-C(24V50/60HZ)
- Catalogue code: 231687
- Catalogue title: DILEM-01-C(24V50/60HZ) 231687 Y7-231687 EATON ELECTRIC Contactor, 3p+1N/C, 4kW/400V/AC3
More info
▲General specifications
UL File No.: E29096
CSA File No.: 012528
UL 508
CE
IEC/EN 60947-4-1
UL
CSA Class No.: 3211-04
CSA
UL Category Control No.: NLDX
CSA-C22.2 No. 14-05
VDE 0660
Features & Functions
General
150,000 Operations (at 240 V, DC, L/R = 50 ms: 2 contacts in series 0.5 A)
10,000,000 Operations
200,000 Operations (at 240 V, AC-15)
20 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/C auxiliary contact, Basic unit without auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Basic unit without auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (1 - 2.5) mm²
Electrical rating
2.5 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
1.5 A at 100 V, DC L/R ≤ 15 ms (with 3 contacts in series)
0.5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
300 V AC, Between coil and contacts, According to EN 61140
300 V AC, Between coil and auxiliary contacts, According to EN 61140
300 V AC, Between auxiliary contacts, According to EN 61140
Short-circuit rating
5 kA, SCCR (UL/CSA)
6 A gG/gL, Max. Fuse 500V, Auxiliary contacts, Short-circuit rating without welding
10 A fast, Max. Fuse 500V, Auxiliary contacts, Short-circuit rating without welding
Conventional thermal current Ith
Switching capacity
0.5 A, 250 V DC, (UL/CSA)
P300, DC operated (UL/CSA)
Magnet system
26 W, AC, Dual-frequency coil at 50 Hz
29 VA, AC, Dual-frequency coil at 60 Hz
1.8 W, Coil in a cold state and 1.0 x Us
1.8 W, Coil in a cold state and 1.0 x Us
5.4 VA, Coil in a cold state and 1.0 x Us
1.8 W, AC, Dual-frequency coil at 60 Hz