View larger
DILDC600/22(RDS250) 183315 Y7-183315 EATON ELECTRIC DC contactor, 2-pole + 2 N/O + 2 N/C, 600 A/DC-1, 1000v
DILDC600/22(RDS250)
183315
Y7-183315
EATON - MOELLER
1 Pcs.
Automation > Power contactor, DC switching
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller DILDC600/22(RDS250) DC contactor provides robust switching capabilities for high-current direct current distribution networks. Power contactors of this grade are commonly specified in heavy industrial machinery, battery energy storage systems, and traction applications for reliable circuit control. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILDC600/22(RDS250)
- Catalogue code: 183315
More info
▲General specifications
UL
CSA
CSA Class No.: C321124
UL508
IEC/EN 60947-5-1
CSA File No.: 012528
UL File No.: E338590
IEC/EN 60947-4-1
CE
CSA-C22.2 No. 14-05
Global
1,000,000 Operations (AC operated)
1000 mechanical Operations/h (DC operated)
1000 mechanical Operations/h (AC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
General
Damp heat, cyclic, to IEC 60068-2-30
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
1 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Control circuit cables
2 x (18 - 12)
M10, Terminal screw, Main connections
0.8 x 5.5/1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver
24 Nm, Main cable connection screw/bolt
Terminal capacities
Max. 900 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 1000 V DC, Main conducting paths
Max. 900 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 690 V DC, Main conducting paths
Max. 900 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 1000 V DC, Main conducting paths
Max. 900 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 400 V DC, Main conducting paths
1000 V, Between control inputs and main contacts, According to EN 61140
1000 V, Between the contacts, According to EN 61140
Electrical rating
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Max. 900 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 1000 V DC, Main conducting paths
Max. 900 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 690 V DC, Main conducting paths
Max. 900 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 1000 V DC, Main conducting paths
Max. 900 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 400 V DC, Main conducting paths
1000 V, Between control inputs and main contacts, According to EN 61140
1000 V, Between the contacts, According to EN 61140
Switching capacity
AC operated: 0.2 x US max - 0.6 x US min, AC operated
0.7 - 1.15 V AC x Us
550 W, Pull-in power, Coil in a cold state and 1.0 x Us
600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
18 VA, Coil in a cold state and 1.0 x Us
9.5 W, Coil in a cold state and 1.0 x Us
Magnet system
600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
18 VA, Coil in a cold state and 1.0 x Us
9.5 W, Coil in a cold state and 1.0 x Us