DILDC500/22(RDS250) 186873 Y7-186873 EATON ELECTRIC DC contactor, 2 pole + 2 N/O + 2 N/C, 500 A/DC-1, 1000V
DILDC500/22(RDS250)
186873
Y7-186873
EATON - MOELLER
1 Pcs.
Automation > Power contactor, DC switching
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-capacity electrical control, the Eaton Moeller DILDC500/22(RDS250) DC contactor securely switches heavy direct current loads in industrial systems. Heavy-duty contactors are deployed in renewable energy installations, heavy machinery, and DC motor drives to safely manage high-voltage power distribution. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Manufacturer: Eaton Moeller
- Manufacturer part number: DILDC500/22(RDS250)
- Catalogue code: 186873
More info
▲General specifications
UL File No.: E338590
CSA-C22.2 No. 14-05
UL
CSA File No.: 012528
CSA
CSA Class No.: C321124
CE
IEC/EN 60947-5-1
IEC/EN 60947-4-1
UL508
Global
1,000,000 Operations (DC operated)
1000 mechanical Operations/h (DC operated)
1000 mechanical Operations/h (AC operated)
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
General
Damp heat, constant, to IEC 60068-2-78
8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
1 x (0.75 - 2.5) mm², Control circuit cables
1 x (0.75 - 2.5) mm², Control circuit cables
1/0 - 500 MCM, Main cables
M3.5, Terminal screw, Control circuit cables
2, Terminal screw, Control circuit cables, Pozidriv screwdriver
1.2 Nm, Screw terminals, Control circuit cables
Terminal capacities
Max. 700 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 1000 V DC, Main conducting paths
Max. 700 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 690 V DC, Main conducting paths
Max. 700 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 1000 V DC, Main conducting paths
Max. 700 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 690 V DC, Main conducting paths
Max. 700 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 400 V DC, Main conducting paths
1000 V, Between the contacts, According to EN 61140
1000 V, Between auxiliary contacts and main contacts, According to EN 61140
Electrical rating
15 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)
Max. 700 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 1000 V DC, Main conducting paths
Max. 700 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 690 V DC, Main conducting paths
Max. 700 A gR 1000 V DC (max. short-circuit current 6 kA), Fuse, Type “2” coordination, 1000 V DC, Main conducting paths
Max. 700 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 690 V DC, Main conducting paths
Max. 700 A gR 1000 V DC (max. short-circuit current 30 kA), Fuse, Type “1” coordination, 400 V DC, Main conducting paths
1000 V, Between the contacts, According to EN 61140
1000 V, Between auxiliary contacts and main contacts, According to EN 61140
Switching capacity
0.2 x US max - 0.6 x US min, DC operated
0.7 - 1.15 V DC x Us
550 W, Pull-in power, Coil in a cold state and 1.0 x Us
600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
9.5 W, Coil in a cold state and 1.0 x Us
18 VA, Coil in a cold state and 1.0 x Us
24 V DC
Magnet system
600 VA, Pull-in power, Coil in a cold state and 1.0 x Us
9.5 W, Coil in a cold state and 1.0 x Us
18 VA, Coil in a cold state and 1.0 x Us
24 V DC