DILA-XHI22-PI 199319 Y7-199319 EATON ELECTRIC DILA-XHI22-PI
DILA-XHI22-PI
199319
Y7-199319
EATON - MOELLER
5 Pcs.
Automation > Auxiliary contact block
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILA-XHI22-PI auxiliary contact block is mounted to control relays and contactors to increase the number of available switching pathways for interlocking and signaling schemes. It facilitates complex automation logic by tracking the operational state of the primary switching device. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact (EF008257): 0
- Number of contacts as normally open contact (EF008256): 2
- Number of contacts as normally closed contact (EF008255): 2
- Number of fault-signal switches (EF007613): 0
- Rated operation current Ie at AC-15, 230 V (EF001385): 4 A
- Type of electric connection (EF003961): Spring clamp connection
- Model (EF000010): Clip-on
- Mounting method (EF000003): Front fastening
More info
▲General specifications
VDE 0660
CSA File No.: 012528
CSA Class No.: 3211-03
UL File No.: E29184
UL 508
CSA-C22.2 No. 14-05
CE marking
UL
CSA
UL Category Control No.: NKCR
Features & Functions
General
5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10,000,000 Operations (AC operated)
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (0.5 - 2.5) mm²
2 x (0.5 - 2.5) mm², Push-in terminals, ferrule to DIN 46228-1
1 x (0.5 - 1.5) mm², Push-in terminals, ferrule to DIN 46228-4
2 x (0.5 - 2.5) mm²
2 x (0.5 - 2.5) mm², Control circuit cables
Electrical rating
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
2.5 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
0.25 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
1 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
0.5 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
400 V AC, Between auxiliary contacts, According to EN 61140
1 A, 250 V DC, (UL/CSA)
P300, DC operated (UL/CSA)