View larger
DILA-40(42V50HZ,48V60HZ)-PI 199207 Y7-199207 EATON ELECTRIC DILA-40(42V50HZ,48V60HZ)-PI
DILA-40(42V50HZ,48V60HZ)-PI
199207
Y7-199207
EATON - MOELLER
1 Pcs.
Automation > Contactor relay
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DILA-40(42V50HZ,48V60HZ)-PI 199207 Y7-199207 is a versatile control relay designed for switching auxiliary circuits and managing industrial automation logic. These components provide reliable performance in applications requiring high switching frequency and dependable electrical isolation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 42 V
- Rated control supply voltage AC 60 Hz (EF003979): 48 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Rated operation current (EF007679): 16 A
- Rated operation current Ie, 400 V (EF001378): 4 A
- Mounting method (EF000003): DIN-rail/screw
- With LED indication (EF005950): No
- Suitable for manual operation (EF002978): No
- Interface (EF000594): No
- Operating voltage AC 50 Hz (EF008206): 17 V
- Operating voltage AC 60 Hz (EF008207): 17 V
- Operating voltage DC (EF008208): 24 V
- Voltage type (operating voltage) (EF005294): AC/DC
- Rated switch current (EF006706): 16 A
- Connection type auxiliary circuit (EF006820): Spring clamp connection
More info
▲General specifications
EN 60947-5-1
VDE 0660
CSA File No.: 012528
CSA Class No.: 3211-03
UL File No.: E29184
UL 508
CSA-C22.2 No. 14-05
CE marking
UL Category Control No.: NKCR
UL
CSA
Features & Functions
General
5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (0.5 - 2.5) mm²
Electrical rating
4 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
2 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
1 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
4 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
16 A
400 V AC, Between coil and auxiliary contacts, According to EN 61140
1 A, 250 V DC, (UL/CSA)
P300, DC operated (UL/CSA)
Magnet system
Communication
Contacts
λ < 5 x 1/10⁷ (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)