View larger
DILA-31(380V50HZ,440V60HZ) 276365 Y7-276365 EATON ELECTRIC Contactor switching 3 NO + 1 NC 380 V 50 HZ, 440 ..
DILA-31(380V50HZ,440V60HZ)
276365
Y7-276365
EATON - MOELLER
1 Pcs.
Automation > Contactor relay
Contactors up to 170A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The DILA-31(380V50HZ,440V60HZ) 276365 Y7-276365 EATON ELECTRIC Contactor switching 3 NO + 1 NC 380 V 50 HZ, 440 .. is an Eaton Moeller contactor relay utilized for switching auxiliary and control circuits in industrial machinery and electrical distribution systems. It ensures dependable signal handling and interlocking within control architecture.
Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 380 V
- Rated control supply voltage AC 60 Hz (EF003979): 440 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Rated operation current (EF007679): 16 A
- Rated operation current Ie, 400 V (EF001378): 4 A
- Mounting method (EF000003): Screw
- With LED indication (EF005950): No
- Suitable for manual operation (EF002978): No
- Interface (EF000594): No
- Operating voltage AC 50 Hz (EF008206): 17 V
- Operating voltage AC 60 Hz (EF008207): 17 V
- Operating voltage DC (EF008208): 24 V
- Voltage type (operating voltage) (EF005294): AC/DC
- Rated switch current (EF006706): 16 A
- Connection type auxiliary circuit (EF006820): Screw connection
More info
▲General specifications
CSA Std. C22.2 No. 14-05
EN 60947-4-1
IEC 60947-4-1
VDE
UL
CSA
CSA-C22.2 No. 14-05
IEC/EN 60947-4-1
UL Category Control No.: NKCR
CE
CSA Class No.: 3211-03
CSA File No.: 012528
UL File No.: E29184
EN 60947-5-1
IEC/EN 60947
VDE 0660
Features & Functions
General
5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (0.75 - 2.5) mm², Screw terminals
2 x (0.75 - 2.5) mm², Screw terminals
2, Terminal screw, Pozidriv screwdriver
Electrical rating
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
4 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
4 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
2 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
16 A
400 V AC, Between coil and auxiliary contacts, According to EN 61140
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)