View larger
DILM820-XHI11V-SI 208283 Y7-208283 EATON ELECTRIC Auxiliary contact module 1 NO early-make + 1 NC late-break..
DILM820-XHI11V-SI
208283
Y7-208283
EATON - MOELLER
1 Pcs.
Automation > Auxiliary contact block
Contactors more than 170 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller builds the DILM820-XHI11V-SI auxiliary contact module to manage specialized timing sequences in motor control circuits. Units featuring staggered contact actions help sequence electrical operations safely by introducing precise delays between switching events. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact (EF008257): 0
- Number of contacts as normally open contact (EF008256): 1
- Number of contacts as normally closed contact (EF008255): 1
- Number of fault-signal switches (EF007613): 0
- Rated operation current Ie at AC-15, 230 V (EF001385): 6 A
- Type of electric connection (EF003961): Screw connection
- Model (EF000010): Clip-on
- Mounting method (EF000003): Side mounting
More info
▲General specifications
UL
VDE 0660
UL Category Control No.: NKCR
CE
UL 508
IEC/EN 60947-4-1
CSA
CSA File No.: 012528
CSA-C22.2 No. 14-05
UL File No.: E29184
IEC/EN 60947
Features & Functions
General
6000 V
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm²
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Electrical Rating
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
Short-circuit rating
FAZ-C4/1, Maximum overcurrent protective device, Short-circuit rating without welding, Short-circuit protection only, Contacts
Conventional thermal current
Switching capacity
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Communication
Contacts
1 (normally closed, late break)
Safety
440 V AC, Between auxiliary contacts and main contacts, According to EN 61140
440 V AC, Between coil and auxiliary contacts, According to EN 61140