View larger
DILA-XHICV22 276535 XTCEXFCLCC22 EATON ELECTRIC Auxiliary contact module, 1N/O+1N/O early+1N/C+1N/C late, su..
DILA-XHICV22
276535
XTCEXFCLCC22
EATON - MOELLER
1 Pcs.
Automation > Auxiliary contact block
KDIL Accessories
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DILA-XHICV22 auxiliary contact module provides expanded switching capacity for contactors and control relays, enabling additional feedback and interlocking paths in automated electrical systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact (EF008257): 0
- Number of contacts as normally open contact (EF008256): 2
- Number of contacts as normally closed contact (EF008255): 2
- Number of fault-signal switches (EF007613): 0
- Rated operation current Ie at AC-15, 230 V (EF001385): 4 A
- Type of electric connection (EF003961): Spring clamp connection
- Model (EF000010): Clip-on
- Mounting method (EF000003): Front fastening
More info
▲General specifications
IEC 60947-4-1
EN 60947-4-1
UL 508
CSA
IEC/EN 60947
IEC/EN 60947-4-1
VDE 0660
UL File No.: E29184
UL Category Control No.: NKCR
CSA File No.: 012528
CE
CSA-C22.2 No. 14-05
UL
CSA Class No.: 3211-03
Features & Functions
General
5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10,000,000 Operations (AC operated)
DILM(C)
DILA
DILMP
DILL
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0.75 - 1.5) mm², Spring-loaded terminals
2 x (0.75 - 2.5) mm², Spring-loaded terminals
Electrical rating
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
2.5 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
0.5 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
0.25 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series)
400 V AC, Between coil and auxiliary contacts, According to EN 61140
10 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)
Communication
Contacts
53 in combination with DILA(C)-31
62 in combination with DILA(C)-40
1 (normally closed, late break)