View larger
DILA-XHIC31 276533 XTCEXFACC31 EATON ELECTRIC Auxiliary contact module, 3N/O+1N/C, surface mounting, spring ..
DILA-XHIC31
276533
XTCEXFACC31
EATON - MOELLER
5 Pcs.
Automation > Auxiliary contact block
KDIL Accessories
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
DILA-XHIC31 276533 XTCEXFACC31 EATON ELECTRIC Auxiliary contact module, 3N/O+1N/C, surface mounting, spring .. provides modular auxiliary switching for contactor relays, allowing control panels to execute complex interlocking and signaling routines. These clip-on modules enhance control flexibility in industrial machine safety and automation networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact (EF008257): 0
- Number of contacts as normally open contact (EF008256): 3
- Number of contacts as normally closed contact (EF008255): 1
- Number of fault-signal switches (EF007613): 0
- Rated operation current Ie at AC-15, 230 V (EF001385): 4 A
- Type of electric connection (EF003961): Spring clamp connection
- Model (EF000010): Clip-on
- Mounting method (EF000003): Front fastening
More info
▲General specifications
UL File No.: E29184
UL 508
IEC/EN 60947
UL Category Control No.: NKCR
CSA File No.: 012528
VDE 0660
CE
CSA Class No.: 3211-03
CSA
CSA-C22.2 No. 14-05
UL
Features & Functions
Switching elements according to EN 50005
General
7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
10,000,000 Operations (AC operated)
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (0.75 - 1.5) mm², Spring-loaded terminals
1 x (0.75 - 2.5) mm², Spring-loaded terminals
Electrical rating
0.5 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series)
10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series)
3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series)
0.25 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series)
6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)
1 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series)
5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series)
6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series)
1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series)
10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series)
400 V AC, Between auxiliary contacts, According to EN 61140
10 A, 600 V AC, (UL/CSA)
P300, DC operated (UL/CSA)
Communication
Contacts
53 in combination with DILA(C)-22
71E in combination with DILA(C)-40