EATON - MOELLER DG1-35820FB-C00C DG1-35820FB-C00C 3-4918-312A EATON ELECTRIC Variable frequency drive, 600 V AC, 3-phase, 750 A, 500 kW, IP00.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DG1-35820FB-C00C 3-4918-312A EATON ELECTRIC Variable frequency drive, 600 V AC, 3-phase, 750 A, 500 kW, IP00..

DG1-35820FB-C00C

3-4918-312A

3-4918-312A

EATON - MOELLER

1 Pcs.

Variable frequency drive, 600 V AC, 3-phase, 750 A, 500 kW, IP00, Brake chopper, DC link choke Frequency converter; Ent: 3 x 600 V; Salt: 3 x 600 V; 750; 500 kW; IP00; Transistor braking; DC link choke

Automation > Frequency converter less than 1 kV
Power XL Frequency Converters

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Variable frequency drive, 600 V AC, 3-phase, 750 A, 500 kW, IP00, Brake chopper, DC link choke
Frequency inverter, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 600 V AC, 3-phase, 690 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, 690 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 500 (-10%) - 600 (+10%) V, Rated operational current At 150% overload: Ie = 750 A, Note: Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload, Rated operational current At 110% overload: Ie = 820 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 525 V, 50 Hz, Assigned motor rating 150 % Overload: P = 500 kW, 110 % Overload: P = 560 kW, 150 % Overload: IM = 720 A, 110 % Overload: IM = 770 A, Assigned motor rating Note: at 600 V, 50 Hz, Assigned motor rating 150 % Overload: P = 560 kW, 110 % Overload: P = 630 kW, 150 % Overload: IM = 680 A, 110 % Overload: IM = 765 A, Assigned motor rating Note: at 690 V, 60 Hz, Assigned motor rating 150 % Overload: P = 900 HP, 110 % Overload: P = 1000 HP, Assigned motor rating 150 % Overload: IM = 729 A, 110 % Overload: IM = 810 A, Degree of Protection: IP00, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, Brake chopper, DC link choke, Frame size: FS8, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5
[

Delivery program

Product range
Variable frequency drives
Part group reference (e.g. DIL)
DG1
Rated operational voltage [Ue]
600 V AC, 3-phase
690 V AC, 3-phase
Output voltage with Ve[U2]
600 V AC, 3-phase
690 V AC, 3-phase
Mains voltage (50/60Hz) [ULN]
500 (-10%) - 600 (+10%) V
Rated operational current [Ie]
At 150% overload [Ie]
750 A
At 110% overload [Ie]
820 A
Note
Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload
Assigned motor rating
Note
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz
Note
Overload cycle for 60 s every 600 s
Note
at 525 V, 50 Hz
150 % Overload [P]
500 kW
110 % Overload [P]
560 kW
150 % Overload [IM]
720 A
110 % Overload [IM]
770 A
Note
at 600 V, 50 Hz
150 % Overload [P]
560 kW
110 % Overload [P]
630 kW
150 % Overload [IM]
680 A
110 % Overload [IM]
765 A
Note
at 690 V, 60 Hz
150 % Overload [P]
900 HP
110 % Overload [P]
1000 HP
150 % Overload [IM]
729 A
110 % Overload [IM]
810 A
Degree of Protection
IP00
Interface/field bus (built-in)
Modbus RTU
Modbus TCP
BACnet MS/TP
Ethernet IP
Fieldbus connection (optional)
PROFIBUS
CANopen®
DeviceNet
SmartWire-DT
Fitted with
Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
Brake chopper
DC link choke
Frame size
FS8
Connection to SmartWire-DT
yes
in conjunction with DXG-NET-SWD SmartWire DT module
,

Technical data

General
Standards
Specification for general requirements: IEC/EN 61800-2
EMC requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5
Certifications
CE, UL, cUL, c-Tick, UkrSEPRO, EAC
Production quality
RoHS, ISO 9001
Climatic proofing [ρw]
< 95%, average relative humidity (RH), non-condensing, non-corrosive %
Air quality
3C2, 3S2
Ambient temperatureoperation (150 % overload) [ϑ]
-10 - +40 (max. +50 with 1% derating per Kelvin temperature increase) °C
Ambient temperatureoperation (110 % overload) [ϑ]
-10 - +40 (max. +50 with 1% derating per Kelvin temperature increase) °C
Ambient temperatureStorage [ϑ]
-40 - +70 °C
Overvoltage category
III
Pollution degree
2
Radio interference levelRadio interference class (EMC)
C1 (with external filter, for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Radio interference levelEnvironment (EMC)
1st and 2nd environments as per EN 61800-3
Radio interference levelmaximum motor cable length [I]
C3 ≤ 10 m m
Mechanical shock resistance
EN 61800-5-1, EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging) g
Vibration
EN 61800-5-1, EN 60068-2-6: 5 - 150 Hz
Amplitude: 1 mm (peak) at 5 - 15.8 Hz
Maximum acceleration amplitude: 1 g at 15.8 – 150 Hz
Mounting position
Vertical
Altitude
0 - 1000 m above sea level
Above 1000 m: 1% derating for every 100 m
max. 2000 m m
Degree of Protection
IP00
Protection against direct contact
BGV A3 (VBG4, finger- and back-of-hand proof)
Main circuit
SupplyRated operational voltage [Ue]
600 V AC, 3-phase
690 V AC, 3-phase
SupplyMains voltage (50/60Hz) [ULN]
500 (-10%) - 600 (+10%) V
SupplyInput current (150% overload) [ILN]
739 A
SupplyInput current (110% overload) [ILN]
813 T
SupplySystem configuration
TN-S, TN-C, TN-C-S, TT, IT
SupplySupply frequency [fLN]
50/60 Hz
SupplyFrequency range [fLN]
45–66 (± 0%) Hz
SupplyMains switch-on frequency
Maximum of one time every 60 seconds
SupplyMains current distortion [THD]
28 %
SupplyRated conditional short-circuit current [Iq]
< 65 kA
Power sectionFunction
Variable frequency drive with internal DC link, DC link choke and IGBT inverter
Power sectionOverload current (150% overload) [IL]
1125 A
Power sectionOverload current (110% overload) [IL]
902 A
Power sectionmax. starting current (High Overload) [IH]
200 %
Power sectionNote about max. starting current
for 2 seconds every 20 seconds
Power sectionOutput voltage with Ve[U2]
600 V AC, 3-phase
690 V AC, 3-phase
Power sectionOutput Frequency [f2]
0 - 50/60 (max. 400) Hz
Power sectionSwitching frequency [fPWM]
2
adjustable 1.5 - 6 kHz
Power sectionOperation Mode
U/f control
Speed control with slip compensation
sensorless vector control (SLV)
Torque regulation
Power sectionFrequency resolution (setpoint value) [Δf]
0.01 Hz
Power sectionRated operational currentAt 150% overload [Ie]
750 A
Power sectionRated operational currentAt 110% overload [Ie]
820 A
Power sectionNote
Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload
Power sectionMotor current limit [I]
0.1 - 2 x IH(CT) A
Power sectionPower lossHeat dissipation at rated operational current Ie=110% [PV]
16617 W
Power sectionEfficiency [η]
98.1 %
Power sectionFan
temperature controlled
externally accessible
Power sectionInternal fan delivery rate
2800 m3/h
Power sectionFitted with
Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
Brake chopper
DC link choke
Power sectionSafety function
STO (Safe Torque Off, SIL1, PLc Cat 1)
Power sectionFrame size
FS8
Motor feederNote
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz
Motor feederNote
Overload cycle for 60 s every 600 s
Motor feederNote
at 525 V, 50 Hz
Motor feeder150 % Overload [P]
500 kW
Motor feeder110 % Overload [P]
560 kW
Motor feederNote
at 600 V, 50 Hz
Motor feeder150 % Overload [P]
560 kW
Motor feeder110 % Overload [P]
630 kW
Motor feederNote
at 690 V, 60 Hz
Motor feeder150 % Overload [P]
900 HP
Motor feeder110 % Overload [P]
1000 HP
Motor feedermaximum permissible cable length [I]
screened: 200 m
Motor feederApparent powerApparent power at rated operation 600 V [S]
852.2 kVA
Motor feederApparent powerApparent power at rated operation 690 V [S]
980 kVA
Motor feederBraking functionStandard braking torque
max. 30 % MN
Motor feederBraking functionDC braking torque
adjustable to 150 %
Motor feederBraking functionBraking torque with external braking resistance
Max. 100% of rated operational current Ie with external braking resistor
Motor feederBraking functionminimum external braking resistance [Rmin]
2.5 Ω
Motor feederBraking functionSwitch-on threshold for the braking transistor [UDC]
Supply voltage UAUX 1050 V DC V
Motor feederBraking functionDC braking [%]
≦ 150, adjustable I/Ie
Control section
External control voltage [Uc]
24 V DC (max. 250 mA options incl.) V
Reference voltage [Us]
10 V DC (max. 10 mA) V
Analog inputs
2, parameterizable, 0 - 10 V DC, 2 - 10 V DC, -10 - +10 V DC, 0/4 - 20 mA
Analog outputs
2, parameterizable, 0 - 10 V, 0/4 - 20 mA
Digital inputs
8, parameterizable, max. 30 V DC
Digital outputs
1, parameterizable, 24 V DC
Relay outputs
3, parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 VAC) / 6 A (24 VDC)
Interface/field bus (built-in)
Modbus RTU
Modbus TCP
BACnet MS/TP
Ethernet IP
Expansion slots
2
Assigned switching and protective elements
Power WiringSafety device (fuse or miniature circuit-breaker)IEC (Type B, gG), 150 %
NZMN4-AE800
Power WiringSafety device (fuse or miniature circuit-breaker)IEC (Type B, gG), 110 %
NZMC3-A400
Power WiringSafety device (fuse or miniature circuit-breaker)UL (Class CC or J)
2 A
Power WiringMains contactor150 % overload (CT/IH, at 50 °C)
DILM580
Power WiringMains contactor110 % overload (VT/IL, at 40 °C)
DILM650
Power WiringMain choke150 % overload (CT/IH, at 50 °C)
Integrated DC link choke, uk = 5%
Power WiringMain choke110 % overload (VT/IL, at 40 °C)
Integrated DC link choke, uk = 5%
Power WiringNote regarding radio interference suppression filter
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
DC link connectionBraking resistance10 % duty factor (DF)
P:2 x DX-BR006-33K3
DC link connectionBraking resistance20 % duty factor (DF)
R:2 x DX-BR002-102K4
DC link connectionBraking resistance40 % duty factor (DF)
?
DC link connectionBraking resistanceNotes concerning braking resistances:
P:n = "n" resistors connected in parallel
R:m = "m" resistors connected in series
,

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
750 A
Equipment heat dissipation, current-dependent [Pvid]
16617 W
Static heat dissipation, non-current-dependent [Pvs]
291 W
Operating ambient temperature min.
-10 °C
Operating ambient temperature max.
+50 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
,

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Frequency converter =< 1 kV (EC001857)
Electric engineering, automation, process control engineering / Electrical drive / Static frequency converter / Static frequency converter = < 1 kV ([email protected] [AKE177014])
Mains voltage
525 - 600 V
Mains frequency
50/60 Hz
Number of phases input
3
Number of phases output
3
Max. output frequency
400 Hz
Max. output voltage
600 V
Nominal output current I2N
820 A
Max. output at quadratic load at rated output voltage
597 kW
Max. output at linear load at rated output voltage
485 kW
Relative symmetric net frequency tolerance
10 %
Relative symmetric net voltage tolerance
10 %
Number of analogue outputs
2
Number of analogue inputs
2
Number of digital outputs
1
Number of digital inputs
8
With control unit
Yes
Application in industrial area permitted
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
Yes
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
1
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
Yes
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP00
Degree of protection (NEMA)
Other
Height
1538 mm
Width
1012 mm
Depth
561 mm
,

Approvals

UL File No.
E134360
UL Category Control No.
NMMS, NMMS7
Suitable for
Branch circuits
Max. Voltage Rating
3~690 V AC IEC: TN-S UL/CSA: 'Y' (Solidly Grounded Wey)
Degree of Protection
IP00
]

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.