View larger
DG1-353D3FB-C54C 9703-1102-00P EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 3.3 A, 1.5 kW, IP..
DG1-353D3FB-C54C
9703110200P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
DG1-353D3FB-C54C 9703-1102-00P EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 3.3 A, 1.5 kW, IP.. is a robust variable frequency drive designed for controlling motor speed, torque, and directional output in manufacturing plants. These motor controllers offer precise electronic regulation to support continuous duty cycles across diverse electro-mechanical applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 525 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 3.3 A
- Power consumption (EF000346): 94 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8 With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
UL508
CUL
EAC
IEC/EN61800-5
UkrSEPRO
UL Category Control No.: NMMS, NMMS7
CE
IEC/EN 61800-3
Specification for general requirements: IEC/EN 61800-2
RoHS, ISO 9001
UL
Safety requirements: IEC/EN 61800-5
C-Tick
UL File No.: E134360
UL report applies to both US and Canada
CSA-C22.2 No. 274-13
Features & Functions
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
100 m, screened, maximum permissible, Motor feeder
NEMA 12
Control unit
PC connection
Radio interference suppression filter
DC link choke
Breaking resistance
Internal DC link
Additional PCB protection
Multi-line graphic display
IGBT inverter
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C1: with external filter, for conducted emissions only
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
UPS drop test (for weights inside the UPS frame)
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Climatic environmental conditions
Max. 1000 m
Max. 2000 m
Main circuit
Speed control with slip compensation
U/f control
Torque regulation
Motor rating
Apparent power
Braking function
Adjustable to 150 % (I/Ie), DC - Main circuit
Adjustable to 150 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Control circuit
Communication
BACnet MS/TP, built in
DeviceNet, optional
Modbus RTU, built in
Ethernet IP, built in
SmartWire-DT, optional
Modbus TCP, built in
PROFIBUS, optional
In conjunction with DXG-NET-SWD SmartWire DT module
PROFINET IO
DeviceNet
TCP/IP
MODBUS
PROFIBUS
Other bus systems
BACnet
EtherNet/IP