View larger
DG1-35208FN-C54C 9703-6106-00P EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 208 A, 132 kW, IP..
DG1-35208FN-C54C
9703610600P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DG1-35208FN-C54C is a variable frequency drive engineered for heavy industrial motor control applications. Large-scale drives of this type regulate high-capacity electrical machinery, delivering smooth start-up sequences and accurate speed adjustments to maximize plant productivity.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 525 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 208 A
- Power consumption (EF000346): 3165 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL File No.: E134360
CUL
CSA-C22.2 No. 274-13
IEC/EN61800-3
Safety requirements: IEC/EN 61800-5
Certified by UL for use in Canada
UkrSEPRO
UL
UL Category Control No.: NMMS, NMMS7
UL508
EAC
IEC/EN61800-5
CE
IEC/EN 61800-3
UL report applies to both US and Canada
RoHS, ISO 9001
C-Tick
Features & Functions
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C3 ≤ 10 m, Radio interference level, maximum motor cable length
IP54
Internal DC link
Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
PC connection
IGBT inverter
Control unit
C1: with external filter, for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
UPS drop test (for weights inside the UPS frame)
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Climatic environmental conditions
Max. 2000 m
Max. 1000 m
Main circuit
Torque regulation
Sensorless vector control (SLV)
Speed control with slip compensation
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Control circuit
Communication
Modbus RTU, built in
PROFIBUS, optional
CANopen®, optional
Ethernet IP, built in
SmartWire-DT, optional
BACnet MS/TP, built in
DeviceNet, optional
Yes
TCP/IP
MODBUS
BACnet
PROFINET IO
DeviceNet
CAN
PROFIBUS
EtherNet/IP