DG1-35010FB-C21C 9703-2002-00P EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 10 A, 5.5 kW, IP2..
DG1-35010FB-C21C
9703200200P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
DG1-35010FB-C21C 9703-2002-00P EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 10 A, 5.5 kW, IP2.. is a high-performance inverter drive utilized to control electric motor speeds in industrial automation systems. By regulating output frequency and voltage, it provides efficient energy management and precise motion regulation for mechanical loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 525 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 10 A
- Power consumption (EF000346): 221 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL File No.: E134360
IEC/EN 61800-3
RoHS, ISO 9001
UL
UL report applies to both US and Canada
IEC/EN61800-5
UkrSEPRO
Certified by UL for use in Canada
CUL
IEC/EN61800-3
Safety requirements: IEC/EN 61800-5
UL Category Control No.: NMMS, NMMS7
C-Tick
CE
Specification for general requirements: IEC/EN 61800-2
EAC
UL508
Features & Functions
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C3 ≤ 10 m, Radio interference level, maximum motor cable length
NEMA 1
Additional PCB protection
Breaking resistance
Radio interference suppression filter
Multi-line graphic display
DC link choke
Internal DC link
Control unit
PC connection
IGBT inverter
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
U/f control
Speed control with slip compensation
Sensorless vector control (SLV)
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Control circuit
Communication
Ethernet IP, built in
SmartWire-DT, optional
Modbus TCP, built in
DeviceNet, optional
PROFIBUS, optional
Modbus RTU, built in
BACnet MS/TP, built in
Yes
TCP/IP
CAN
Other bus systems
DeviceNet
PROFIBUS
PROFINET IO
BACnet
EtherNet/IP