View larger
DG1-345D6FB-C54C 9702-1107-00P Y7-9702-1107-00P EATON ELECTRIC DG1-345D6FB-C54C Variable frequency drive, 3-..
DG1-345D6FB-C54C
9702110700P
Y7-9702-1107-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
As a variable frequency drive, the Eaton Moeller DG1-345D6FB-C54C controls AC motor speed and torque within automated mechanical systems. Such drives are widely utilized to optimize energy usage and process precision in pumps, fans, and conveyors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 7.6 A
- Power consumption (EF000346): 105 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-3
UL508
UL report applies to both US and Canada
IEC/EN61800-3
RoHS, ISO 9001
UL Category Control No.: NMMS, NMMS7
IEC/EN61800-5
UL
UL File No.: E134360
C-Tick
CE
CUL
EAC
Specification for general requirements: IEC/EN 61800-2
CSA-C22.2 No. 274-13
Safety requirements: IEC/EN 61800-5
UkrSEPRO
Features & Functions
Tool-less swapping of fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
100 m, screened, maximum permissible, Motor feeder
C2 ≤ 10 m, Radio interference level, maximum motor cable length
NEMA 12
Additional PCB protection
Multi-line graphic display
PC connection
Control unit
Radio interference suppression filter
Brake chopper
Internal DC link
Breaking resistance
IGBT inverter
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C1: with external filter, for conducted emissions only
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Max. 3000 m
Main circuit
Sensorless vector control (SLV)
U/f control
Speed control with slip compensation
500 V AC, 3-phase
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Control circuit
Communication
Modbus RTU, built in
CANopen®, optional
PROFIBUS, optional
BACnet MS/TP, built in
Ethernet IP, built in
SmartWire-DT, optional
DeviceNet, optional
In conjunction with DXG-NET-SWD SmartWire DT module
MODBUS
DeviceNet
CAN
PROFINET IO
Other bus systems
PROFIBUS
TCP/IP
EtherNet/IP