View larger
DG1-344D3FB-C54C 9702-1105-00P Y7-9702-1105-00P EATON ELECTRIC DG1-344D3FB-C54C Variable frequency drive, 3-..
DG1-344D3FB-C54C
9702110500P
Y7-9702-1105-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for precise motor control, this Eaton Moeller DG1-344D3FB-C54C variable frequency drive adjusts electrical parameters to manage AC motor speeds. Industrial drives are standard components in production lines for smooth acceleration, deceleration, and energy conservation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 86 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
C-Tick
UL Category Control No.: NMMS, NMMS7
RoHS, ISO 9001
UL
Safety requirements: IEC/EN 61800-5
Specification for general requirements: IEC/EN 61800-2
UL File No.: E134360
CUL
UL report applies to both US and Canada
Certified by UL for use in Canada
UL508
CE
UkrSEPRO
IEC/EN 61800-3
EAC
IEC/EN61800-5
Features & Functions
Tool-less swapping of fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
C3 ≤ 50 m, Radio interference level, maximum motor cable length
NEMA 12
Brake chopper
Multi-line graphic display
PC connection
Breaking resistance
IGBT inverter
Control unit
DC link choke
Internal DC link
Additional PCB protection
C1: with external filter, for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Climatic environmental conditions
Max. 3000 m
Above 1000 m with 1 % derating per 100 m
Max. 2000 m for Corner Grounded TN Systems
Main circuit
Torque regulation
U/f control
Speed control with slip compensation
480 V AC, 3-phase
500 V AC, 3-phase
500 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 % (I/Ie), DC - Main circuit
Adjustable to 150 %, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Control circuit
Communication
BACnet MS/TP, built in
CANopen®, optional
DeviceNet, optional
PROFIBUS, optional
SmartWire-DT, optional
Ethernet IP, built in
Modbus RTU, built in
In conjunction with DXG-NET-SWD SmartWire DT module
MODBUS
PROFIBUS
TCP/IP
PROFINET IO
BACnet
Other bus systems
DeviceNet
EtherNet/IP