View larger
DG1-343D3FB-C21C 9702-1004-00P Y7-9702-1004-00P EATON ELECTRIC DG1-343D3FB-C21C Variable frequency drive, 3-..
DG1-343D3FB-C21C
9702100400P
Y7-9702-1004-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DG1-343D3FB-C21C variable frequency drive delivers advanced motor control capabilities, allowing precise frequency and torque modulation in automated manufacturing applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 380 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 400 Hz
- Max. output voltage: 500 V
- Nominal output current I2N: 3.3 A
- Power consumption: 73 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 2
- Number of analogue inputs: 2
- Number of digital outputs: 1
- Number of digital inputs: 8
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
CSA-C22.2 No. 274-13
IEC/EN 61800-3
CUL
UL Category Control No.: NMMS, NMMS7
IEC/EN61800-3
RoHS, ISO 9001
UL
UL508
CE
UL report applies to both US and Canada
IEC/EN61800-5
UkrSEPRO
C-Tick
EAC
Specification for general requirements: IEC/EN 61800-2
Certified by UL for use in Canada
UL File No.: E134360
Features & Functions
Temperature-controlled fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
100 m, screened, maximum permissible, Motor feeder
C3 ≤ 50 m, Radio interference level, maximum motor cable length
NEMA 1
PC connection
DC link choke
Brake chopper
Radio interference suppression filter
Internal DC link
Additional PCB protection
Breaking resistance
Control unit
IGBT inverter
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
UPS drop test (for weights inside the UPS frame)
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Max. 2000 m for Corner Grounded TN Systems
Main circuit
Torque regulation
U/f control
Sensorless vector control (SLV)
480 V AC, 3-phase
500 V AC, 3-phase
500 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Control circuit
Communication
Modbus TCP, built in
DeviceNet, optional
PROFIBUS, optional
Ethernet IP, built in
SmartWire-DT, optional
CANopen®, optional
BACnet MS/TP, built in
In conjunction with DXG-NET-SWD SmartWire DT module
PROFINET IO
PROFIBUS
MODBUS
DeviceNet
CAN
Other bus systems
BACnet
EtherNet/IP