View larger
DG1-342D2FB-C54C 9702-1101-00P Y7-9702-1101-00P EATON ELECTRIC DG1-342D2FB-C54C Variable frequency drive, 3-..
DG1-342D2FB-C54C
9702110100P
Y7-9702-1101-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Regulating motor speeds in automated industrial equipment is the primary function of this Eaton Moeller DG1-342D2FB-C54C variable frequency drive. Such units are deployed across manufacturing systems to control electric motor acceleration, deceleration, and operational velocity, helping to optimize overall process efficiency and energy consumption. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.2 A
- Power consumption (EF000346): 59 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL report applies to both US and Canada
EAC
UL Category Control No.: NMMS, NMMS7
CSA-C22.2 No. 274-13
CUL
Specification for general requirements: IEC/EN 61800-2
IEC/EN61800-3
Certified by UL for use in Canada
IEC/EN 61800-3
IEC/EN61800-5
UkrSEPRO
UL
UL File No.: E134360
CE
Safety requirements: IEC/EN 61800-5
UL508
RoHS, ISO 9001
Features & Functions
Temperature-controlled fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
C3 ≤ 50 m, Radio interference level, maximum motor cable length
NEMA 12
Multi-line graphic display
PC connection
IGBT inverter
Brake chopper
Control unit
Radio interference suppression filter
Breaking resistance
Additional PCB protection
Internal DC link
C1: with external filter, for conducted emissions only
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 2000 m for Corner Grounded TN Systems
Max. 1000 m
Main circuit
Speed control with slip compensation
Torque regulation
Sensorless vector control (SLV)
480 V AC, 3-phase
400 V AC, 3-phase
480 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 % (I/Ie), DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Control circuit
Communication
BACnet MS/TP, built in
PROFIBUS, optional
CANopen®, optional
DeviceNet, optional
Ethernet IP, built in
SmartWire-DT, optional
Modbus TCP, built in
Yes
PROFINET IO
BACnet
MODBUS
DeviceNet
TCP/IP
PROFIBUS
CAN
EtherNet/IP