View larger
DG1-342D2FB-C21C 9702-1002-00P Y7-9702-1002-00P EATON ELECTRIC DG1-342D2FB-C21C Variable frequency drive, 3-..
DG1-342D2FB-C21C
9702100200P
Y7-9702-1002-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller variable frequency drive delivers advanced motor control for complex industrial automation tasks, ensuring optimal speed regulation and process reliability. These electronic units dynamically adjust power outputs to match real-time mechanical demands, protecting assets and minimizing energy consumption. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.2 A
- Power consumption (EF000346): 59 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Certified by UL for use in Canada
IEC/EN61800-3
EAC
UL File No.: E134360
IEC/EN 61800-3
UL508
IEC/EN61800-5
CSA-C22.2 No. 274-13
UkrSEPRO
UL report applies to both US and Canada
RoHS, ISO 9001
C-Tick
UL Category Control No.: NMMS, NMMS7
Safety requirements: IEC/EN 61800-5
Specification for general requirements: IEC/EN 61800-2
CUL
UL
Features & Functions
Temperature-controlled fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
C3 ≤ 50 m, Radio interference level, maximum motor cable length
NEMA 1
Internal DC link
IGBT inverter
PC connection
Breaking resistance
Multi-line graphic display
Control unit
Radio interference suppression filter
Brake chopper
DC link choke
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
C1: with external filter, for conducted emissions only
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Climatic environmental conditions
Max. 2000 m for Corner Grounded TN Systems
Above 1000 m with 1 % derating per 100 m
Max. 3000 m
Main circuit
U/f control
Speed control with slip compensation
Torque regulation
500 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 % (I/Ie), DC - Main circuit
Adjustable to 150 %, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Control circuit
Communication
Ethernet IP, built in
Modbus TCP, built in
CANopen®, optional
Modbus RTU, built in
PROFIBUS, optional
DeviceNet, optional
SmartWire-DT, optional
Yes
BACnet
MODBUS
PROFINET IO
Other bus systems
TCP/IP
DeviceNet
PROFIBUS