View larger
DG1-34245FN-C54C 9702-6107-00P Y7-9702-6107-00P EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, ..
DG1-34245FN-C54C
9702610700P
Y7-9702-6107-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing high-capacity motor control, the Eaton Moeller DG1-34245FN-C54C variable frequency drive safely modulates industrial output currents for demanding applications. Such drives are crucial for minimizing energy consumption and preventing mechanical strain in large-scale machinery networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 245 A
- Power consumption (EF000346): 3280 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-3
IEC/EN61800-3
IEC/EN61800-5
UkrSEPRO
RoHS, ISO 9001
UL File No.: E134360
CSA-C22.2 No. 274-13
Safety requirements: IEC/EN 61800-5
UL508
UL report applies to both US and Canada
Certified by UL for use in Canada
UL Category Control No.: NMMS, NMMS7
C-Tick
CE
EAC
UL
Specification for general requirements: IEC/EN 61800-2
Features & Functions
Temperature-controlled fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C3 ≤ 50 m, Radio interference level, maximum motor cable length
200 m, screened, maximum permissible, Motor feeder
NEMA 12
PC connection
Internal DC link
Additional PCB protection
Control unit
DC link choke
Multi-line graphic display
IGBT inverter
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
UPS drop test (for weights inside the UPS frame)
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 1000 m
Max. 2000 m for Corner Grounded TN Systems
Main circuit
U/f control
Sensorless vector control (SLV)
Torque regulation
400 V AC, 3-phase
500 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Control circuit
Communication
Modbus RTU, built in
Ethernet IP, built in
CANopen®, optional
DeviceNet, optional
SmartWire-DT, optional
Modbus TCP, built in
BACnet MS/TP, built in
In conjunction with DXG-NET-SWD SmartWire DT module
PROFINET IO
DeviceNet
Other bus systems
BACnet
CAN
MODBUS
PROFIBUS
EtherNet/IP