View larger
DG1-34087FN-C54C 9702-4111-00P Y7-9702-4111-00P EATON ELECTRIC DG1-34087FN-C54C Variable frequency drive, 3-..
DG1-34087FN-C54C
9702411100P
Y7-9702-4111-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operating as a variable frequency drive, the Eaton Moeller DG1-34087FN-C54C controls AC motor velocity and output characteristics in heavy automation setups. Industrial drives provide dynamic speed regulation to reduce mechanical wear and improve overall system efficiency in manufacturing plants.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 87 A
- Power consumption (EF000346): 1217 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
EAC
CUL
Safety requirements: IEC/EN 61800-5
C-Tick
UL
IEC/EN61800-5
CSA-C22.2 No. 274-13
UL Category Control No.: NMMS, NMMS7
UL report applies to both US and Canada
Specification for general requirements: IEC/EN 61800-2
UL File No.: E134360
CE
UL508
Certified by UL for use in Canada
UkrSEPRO
IEC/EN 61800-3
IEC/EN61800-3
Features & Functions
Temperature-controlled fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
200 m, screened, maximum permissible, Motor feeder
IP54
Radio interference suppression filter
Internal DC link
PC connection
Control unit
DC link choke
Multi-line graphic display
IGBT inverter
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C1: with external filter, for conducted emissions only
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Climatic environmental conditions
Max. 2000 m for Corner Grounded TN Systems
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
Speed control with slip compensation
Sensorless vector control (SLV)
Torque regulation
400 V AC, 3-phase
500 V AC, 3-phase
400 V AC, 3-phase
500 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Control circuit
Communication
PROFIBUS, optional
Modbus TCP, built in
Ethernet IP, built in
CANopen®, optional
DeviceNet, optional
Modbus RTU, built in
BACnet MS/TP, built in
Yes
MODBUS
CAN
PROFINET IO
BACnet
Other bus systems
PROFIBUS
DeviceNet
EtherNet/IP