View larger
DG1-34061FN-C54C 9702-4103-00P Y7-9702-4103-00P EATON ELECTRIC DG1-34061FN-C54C Variable frequency drive, 3-..
DG1-34061FN-C54C
9702410300P
Y7-9702-4103-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller Variable frequency drive (part number DG1-34061FN-C54C) provides advanced motor management, delivering reliable frequency conversion to regulate heavy industrial processes.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 61 A
- Power consumption (EF000346): 758 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
EAC
CE
Safety requirements: IEC/EN 61800-5
IEC/EN61800-3
IEC/EN61800-5
RoHS, ISO 9001
UL report applies to both US and Canada
Certified by UL for use in Canada
UL File No.: E134360
C-Tick
CUL
IEC/EN 61800-3
Specification for general requirements: IEC/EN 61800-2
UkrSEPRO
UL
UL Category Control No.: NMMS, NMMS7
UL508
Features & Functions
Externally accessible fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C3 ≤ 50 m, Radio interference level, maximum motor cable length
C2 ≤ 10 m, Radio interference level, maximum motor cable length
IP54
DC link choke
Additional PCB protection
PC connection
Radio interference suppression filter
Multi-line graphic display
IGBT inverter
Internal DC link
C1: with external filter, for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
UPS drop test (for weights inside the UPS frame)
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 1000 m
Max. 3000 m
Main circuit
U/f control
Torque regulation
Speed control with slip compensation
500 V AC, 3-phase
400 V AC, 3-phase
500 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Control circuit
Communication
Modbus TCP, built in
BACnet MS/TP, built in
DeviceNet, optional
Ethernet IP, built in
SmartWire-DT, optional
Modbus RTU, built in
PROFIBUS, optional
Yes
TCP/IP
PROFINET IO
Other bus systems
MODBUS
BACnet
CAN
PROFIBUS